ARTIFICIAL DISC REPLACEMENT - PRELIMINARY-REPORT WITH A 3-YEAR MINIMUM FOLLOW-UP

被引:99
作者
ENKER, P
STEFFEE, A
MCMILLIN, C
KEPPLER, L
BISCUP, R
MILLER, S
机构
[1] Cleveland Spine and Arthritis Center, Division of Orthopaedic Surgery, Cleveland
[2] Acromed Corporation, Cleveland, OH
关键词
ARTIFICIAL DISC REPLACEMENT; FUSION; DISKECTOMY; JUXTAFUSION DEGENERATION; DISC DESIGN;
D O I
10.1097/00007632-199306150-00017
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Artificial disc replacement was performed in six patients with an average age of 55 years and average follow-up of 3.4 years. Four of the six patients had juxtafusion degeneration, one had multilevel disc degeneration, and one patient had isolated disc resorption. The Acroflex disc (Acromed Corporation, Cleveland, OH), which was used in the replacement, is composed of a rubber core vulcanized to two titanium end plates. The latter have superior posts to provide for initial mechanical fixation and porous in-growth surfaces for long-term fixation. Satisfactory results occurred in four of six patients. Poor results occurred in the presence of deformity that resulted in prosthetic failure and isolated disc resorption. There was an average 8-degrees angular and 2.3-mm translational movement and satisfactory in-growth at all interfaces. Design objectives of endurance, biocompatability, geometry, kinematics, constraint, dynamics, stability, and fail-safe were met; however, this study is preliminary in nature.
引用
收藏
页码:1061 / 1070
页数:10
相关论文
共 35 条
  • [11] Frymoyer J.W., Hanley E.N., Howe J., Kuhlmann D., Matteri R.E., A comparison of radiographic findings in fusion and nonfusion patients ten or more years following lumbar disc surgery, Spine, 4, pp. 435-440, (1979)
  • [12] Frymoyer J.W., Hanley E., Howe J., Kuhlmann D., Matteri R., Disc excision and spine fusion in the management of lumbar disc disease: A minimum ten-year follow-up, Spine, 3, pp. 1-6, (1978)
  • [13] Hedman T.P., Kostuik J.P., Fernie G.R., Hellier W.G., Design of an intervertebral disc prosthesis, Spine, 16, pp. 256-260, (1991)
  • [14] King A.I., Prasad P., Ewing C.L., Mechanism of spinal injury due to cephalocaudad acceleration, Orthop Clin North Am, 6, pp. 19-31, (1975)
  • [15] Kirkaldy-Willis W.H., Burton C.V., Managing Low Back Pain, pp. 105-119, (1992)
  • [16] The Kostuik Artificial Disc, pp. 259-270, (1992)
  • [17] Lee C.K., Accelerated degeneration of the segment adjacent to a lumbar fusion, Spine, 13, pp. 375-377, (1988)
  • [18] Lee C.K., Langrana N.A., Lumbosacral spinal fusion: A biomechanical study, Spine, 9, pp. 574-581, (1984)
  • [19] Prosthetic Intervertebral Disc, pp. 2007-2013, (1991)
  • [20] Lee C.K., Langrana N.A., Parsons J.R., Zimmerman M.C., The Artificial Disc, pp. 79-84, (1991)