FIXATION STRENGTH OF A BIODEGRADABLE SCREW IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

被引:56
作者
KOUSA, P
JARVINEN, TLN
POHJONEN, T
KANNUS, P
KOTIKOSKI, M
JARVINEN, M
机构
[1] UNIV TAMPERE,SCH MED,SF-33101 TAMPERE,FINLAND
[2] TAMPERE UNIV HOSP,DEPT SURG,ORTHOPAED SECT,SF-33521 TAMPERE,FINLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1995年 / 77B卷 / 06期
关键词
D O I
10.1302/0301-620X.77B6.7593103
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the strength of fixation of a biodegradable screw with that of two metal screws in a bone-patellar-tendon-bone (BPTB) graft in the bovine knee. We used 33 fresh BPTB specimens with a circular tibial bone plug of 9 mm in diameter which were anchored in a tibial metaphyseal bone tunnel with either an interference screw (n = 11), an AO cancellous screw (n = 11) or a fibrillated, self-reinforced biodegradable poly-L-lactide screw (n = 11) The mean force to failure (+/-SD) in the three groups was 1358 +/- 348 N, 1081 +/- 331 N and 1211 +/- 362 N, respectively. There was no significant difference in the groups with regard to the linear load or the elastic moduli of the fixation. We conclude that the biodegradable screw is as good as either of the two metal screws in the fixation of a BPTB graft in the bovine knee and can be recommended for ACL reconstruction using this type of graft.
引用
收藏
页码:901 / 905
页数:5
相关论文
共 31 条
[1]   ANTERIOR CRUCIATE LIGAMENT REPLACEMENT USING PATELLAR TENDON - AN EVALUATION OF GRAFT REVASCULARIZATION IN THE DOG [J].
ARNOCZKY, SP ;
TARVIN, GB ;
MARSHALL, JL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :217-224
[2]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[3]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[4]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[5]   ANTERIOR CRUCIATE LIGAMENT - ITS NORMAL RESPONSE AND REPLACEMENT [J].
BUTLER, DL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :910-921
[6]  
CLAES L, 1987, J BIOMED MATER RES-A, V21, P319
[7]   ANTERIOR AND POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN RHESUS-MONKEYS - A HISTOLOGICAL, MICRO-ANGIOGRAPHIC, AND BIOMECHANICAL ANALYSIS [J].
CLANCY, WG ;
NARECHANIA, RG ;
ROSENBERG, TD ;
GMEINER, JG ;
WISNEFSKE, DD ;
LANGE, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (08) :1270-1284
[8]   FRACTURE FIXATION WITH BIODEGRADABLE RODS - 41 CASES OF SEVERE ANKLE FRACTURES [J].
HIRVENSALO, E .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (05) :601-606
[9]   ABSORBABLE POLYGLYCOLIDE PINS IN FIXATION OF DISPLACED FRACTURES OF THE RADIAL HEAD [J].
HIRVENSALO, E ;
BOSTMAN, O ;
ROKKANEN, P .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1990, 109 (05) :258-261
[10]   BIOMECHANICAL EVALUATION OF INTERFERENCE SCREW FIXATION IN A BOVINE PATELLAR BONE TENDON BONE AUTOGRAFT COMPLEX FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
HULSTYN, M ;
FADALE, PD ;
ABATE, J ;
WALSH, WR .
ARTHROSCOPY, 1993, 9 (04) :417-424