FIXATION STRENGTH OF A BIODEGRADABLE SCREW IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

被引:56
作者
KOUSA, P
JARVINEN, TLN
POHJONEN, T
KANNUS, P
KOTIKOSKI, M
JARVINEN, M
机构
[1] UNIV TAMPERE,SCH MED,SF-33101 TAMPERE,FINLAND
[2] TAMPERE UNIV HOSP,DEPT SURG,ORTHOPAED SECT,SF-33521 TAMPERE,FINLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1995年 / 77B卷 / 06期
关键词
D O I
10.1302/0301-620X.77B6.7593103
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the strength of fixation of a biodegradable screw with that of two metal screws in a bone-patellar-tendon-bone (BPTB) graft in the bovine knee. We used 33 fresh BPTB specimens with a circular tibial bone plug of 9 mm in diameter which were anchored in a tibial metaphyseal bone tunnel with either an interference screw (n = 11), an AO cancellous screw (n = 11) or a fibrillated, self-reinforced biodegradable poly-L-lactide screw (n = 11) The mean force to failure (+/-SD) in the three groups was 1358 +/- 348 N, 1081 +/- 331 N and 1211 +/- 362 N, respectively. There was no significant difference in the groups with regard to the linear load or the elastic moduli of the fixation. We conclude that the biodegradable screw is as good as either of the two metal screws in the fixation of a BPTB graft in the bovine knee and can be recommended for ACL reconstruction using this type of graft.
引用
收藏
页码:901 / 905
页数:5
相关论文
共 31 条
[11]   THE TREATMENT OF INJURIES OF THE ANTERIOR CRUCIATE LIGAMENT [J].
JOHNSON, RJ ;
BEYNNON, BD ;
NICHOLS, CE ;
RENSTROM, PAFH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (01) :140-151
[12]   PRIMARY STABILITY OF INTERFERENCE SCREW FIXATION - INFLUENCE OF SCREW DIAMETER AND INSERTION TORQUE [J].
KOHN, D ;
ROSE, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :334-338
[13]   A BIOMECHANICAL COMPARISON OF DIFFERENT SURGICAL TECHNIQUES OF GRAFT FIXATION IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
KUROSAKA, M ;
YOSHIYA, S ;
ANDRISH, JT .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (03) :225-229
[14]   MECHANICAL-PROPERTIES OF BIODEGRADABLE POLY-L-LACTIDE LIGAMENT AUGMENTATION DEVICE IN EXPERIMENTAL ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
LAITINEN, O ;
POHJONEN, T ;
TORMALA, P ;
SAARELAINEN, K ;
VASENIUS, J ;
ROKKANEN, P ;
VAINIONPAA, S .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1993, 112 (06) :270-274
[15]  
LAMBERT KL, 1983, CLIN ORTHOP RELAT R, V172, P85
[16]  
MAJOLA A, 1991, CLIN ORTHOP RELAT R, V268, P260
[17]   INTRAMEDULLARY NAILING OF THE CORTICAL BONE OSTEOTOMIES IN RABBITS WITH SELF-REINFORCED POLY-L-LACTIDE RODS MANUFACTURED BY THE FIBRILLATION METHOD [J].
MANNINEN, MJ ;
POHJONEN, T .
BIOMATERIALS, 1993, 14 (04) :305-312
[18]   STRENGTH OF ANTERIOR CRUCIATE LIGAMENT IN HUMANS AND RHESUS-MONKEYS [J].
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (08) :1074-1082
[19]   BIOMECHANICAL ANALYSIS OF HUMAN LIGAMENT GRAFTS USED IN KNEE-LIGAMENT REPAIRS AND RECONSTRUCTIONS [J].
NOYES, FR ;
BUTLER, DL ;
GROOD, ES ;
ZERNICKE, RF ;
HEFZY, MS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (03) :344-352
[20]  
PASCHAL SO, 1994, CLIN ORTHOPAEDICS, V300, P281