STRENGTH-INTERVAL CURVES IN CANINE MYOCARDIUM AT VERY SHORT CYCLE LENGTHS

被引:8
作者
ALFERNESS, C
BAYLY, PV
KRASSOWSKA, W
DAUBERT, JP
SMITH, WM
IDEKER, RE
机构
[1] DUKE UNIV,MED CTR,DEPT MED,DURHAM,NC 27710
[2] DUKE UNIV,DEPT PATHOL,DURHAM,NC 27706
[3] DUKE UNIV,ENGN RES CTR EMERGING CARDIOVASC TECHNOL,DURHAM,NC
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1994年 / 17卷 / 05期
关键词
STRENGTH-INTERVAL CURVES; SHORT CYCLE LENGTH; VENTRICULAR FIBRILLATION;
D O I
10.1111/j.1540-8159.1994.tb01428.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
While ventricular electrophysiological properties have been intensively studied at normal heart rates, little is known about these properties at the very short cycle lengths (approximately 100 msec), which are present in ventricular fibrillation. We examined refractoriness in the right ventricles of six dogs at stimulation intervals of 80 to 300 msec. Starting at 300 msec, the basic (S-1) cycle length was decremented by 10 msec each beat to 200, 150, or 125 msec. A 1-msec premature (S-2) stimulus of 1, 5, 10, or to mA was then introduced. The S-1-S-2 interval was decremented until capture was lost. The refractory period was considered to be the shortest interval that captured the heart for each S-2 strength. Only pacing episodes that did not induce fibrillation were included. Strength-interval curves maintained the same hyperbolic shape but shifted to very short refractory periods as the S-1-S-1 interval was decreased. At the shortest S-1-S-1 intervals, premature stimuli were capable of capturing the heart without inducing ventricular fibrillation for S-1-S-2 intervals as short as 83 +/- 3 msec. Thus, decremental rapid pacing can produce refractory periods shorter than the cycle length during ventricular fibrillation. This finding suggests that there is no need to postulate a discontinuous jump to new electrophysiological properties or relationships at the onset of fibrillation, but that the capability for fibrillation is an integral part of normal electrophysiological parameters when they are pushed to values that do not occur normally. The results of this study should be useful in the further development of active membrane models and cellular automata models of cellular electrical behavior.
引用
收藏
页码:876 / 881
页数:6
相关论文
共 23 条
[1]  
ABILDSKOV JA, 1991, J CARDIOVASC ELECTR, V2, P45
[2]   RECONSTRUCTION OF ACTION POTENTIAL OF VENTRICULAR MYOCARDIAL FIBERS [J].
BEELER, GW ;
REUTER, H .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 268 (01) :177-210
[3]  
Bollacker K. D., 1991, Proceedings. Computers in Cardiology (Cat. No.90CH3011-4), P525, DOI 10.1109/CIC.1990.144271
[4]   NONUNIFORM EPICARDIAL ACTIVATION AND REPOLARIZATION PROPERTIES OF INVIVO CANINE PULMONARY CONUS [J].
BURGESS, MJ ;
STEINHAUS, BM ;
SPITZER, KW ;
ERSHLER, PR .
CIRCULATION RESEARCH, 1988, 62 (02) :233-246
[5]   A THEORETICALLY AND PRACTICALLY MORE EFFECTIVE METHOD FOR INTERRUPTION OF VENTRICULAR-TACHYCARDIA - SELF-ADAPTING AUTODECREMENTAL OVERDRIVE PACING [J].
CHAROS, GS ;
HAFFAJEE, CI ;
GOLD, RL ;
BISHOP, RL ;
BERKOVITS, BV ;
ALPERT, JS .
CIRCULATION, 1986, 73 (02) :309-315
[6]   SUPERNORMAL EXCITABILITY AS A MECHANISM OF CHAOTIC DYNAMICS OF ACTIVATION IN CARDIAC PURKINJE-FIBERS [J].
CHIALVO, DR ;
MICHAELS, DC ;
JALIFE, J .
CIRCULATION RESEARCH, 1990, 66 (02) :525-545
[7]   ANODAL EXCITATION OF CARDIAC MUSCLE [J].
CRANEFIELD, PF ;
HOFFMAN, BF ;
SIEBENS, AA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1957, 190 (02) :383-390
[8]   A MODEL OF CARDIAC ELECTRICAL-ACTIVITY INCORPORATING IONIC PUMPS AND CONCENTRATION CHANGES [J].
DIFRANCESCO, D ;
NOBLE, D .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1985, 307 (1133) :353-398
[9]   REVISED FORMULATION OF THE HODGKIN-HUXLEY REPRESENTATION OF THE SODIUM CURRENT IN CARDIAC-CELLS [J].
DROUHARD, JP ;
ROBERGE, FA .
COMPUTERS AND BIOMEDICAL RESEARCH, 1987, 20 (04) :333-350
[10]  
ELHARRAR V, 1983, AM J PHYSIOL, V244, pH782, DOI 10.1152/ajpheart.1983.244.6.H782