HLA-B27 SCREENING BY FLOW-CYTOMETRY

被引:22
作者
LINGENFELTER, B
FULLER, TC
HARTUNG, L
HUNTER, J
WITTWER, C
机构
[1] Department of Pathology, University of Utah, Salt Lake, Utah
来源
CYTOMETRY | 1995年 / 22卷 / 02期
关键词
ANKYLOSING SPONDYLITIS; CROSS-REACTIVITY; IMMUNOFLUORESCENCE; MICROLYMPHOCYTOTOXICITY; MONOCLONAL ANTIBODY; SENSITIVITY; SPECIFICITY;
D O I
10.1002/cyto.990220211
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flow cytometric assay for lymphocyte HLA-B27 expression using a two-color direct immunofluorescent assay was compared to traditional microlymphocytotoxicity testing on 209 clinical samples. For the flow cytometric assay, whole blood was mixed with a monoclonal anti-B27 conjugated to fluorescein-isothiocyanate (FITC) and anti-CD3 conjugated to phycoerythrin (PE). The samples were analyzed with flow cytometry by gating on CD3 positive events and anti-B27 staining intensity was evaluated as median channel fluorescence of the histogram peak. The median channel fluorescence was least with B27 negative and B7 negative samples (84 +/- 17), intermediate with samples that were B27 negative but B7 positive (118 +/- 13), and greatest with samples that were B27 positive (155 +/- 13). In addition to cross-reactivity with the B7 antigen (n = 38), the monoclonal anti-B27 cross-reacted with HLA-B37 positive samples (n = 3) and HLA-B39 positive samples (n = 3). Using a median channel fluorescence cutoff of 136, 39 of the 40 B27 positive samples gave positive results in the flow cytometric assay for a sensitivity of 97.6%. The specificity was 95.9% with 7 false positives of 169 B27 negative samples. The flow cytometric HLA-B27 assay is a convenient, useful screening test, For greatest specificity, samples positive by flow cytometry should be confirmed by conventional microlymphocytotoxicity or by use of other monoclonal antibodies directed against B27. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 9 条
[1]  
ALBRECHT J, 1987, CLIN CHEM, V33, P1619
[2]   EPITOPE MAP OF THE HLA-B7 CREG USING AFFINITY-PURIFIED HUMAN ALLOANTIBODY PROBES [J].
FULLER, AA ;
RODEY, GE ;
PARHAM, P ;
FULLER, TC .
HUMAN IMMUNOLOGY, 1990, 28 (03) :306-325
[3]   AN OPTIMIZED METHOD FOR ROUTINE HLA-B27 SCREENING USING FLOW-CYTOMETRY [J].
HULSTAERT, F ;
ALBRECHT, J ;
HANNET, I ;
LANCASTER, P ;
BUCHNER, L ;
KUNZ, J ;
FALKENRODT, A ;
TONGIO, M ;
DEKEYSER, F ;
VEYS, EM ;
NOENS, L ;
MIR, N ;
COSTELLO, C ;
BECKER, R ;
STRAUSS, K .
CYTOMETRY, 1994, 18 (01) :21-29
[4]   IMPROVED FLOW CYTOMETRIC METHOD FOR HLA-B27 TYPING [J].
JANSSEN, WCM ;
ROUWEN, JACN ;
HOFFMANN, JJML .
ANNALS OF CLINICAL BIOCHEMISTRY, 1992, 29 :663-667
[5]  
KENNEDY LJ, 1989, IMMUNOBIOLOGY HLA, V1
[6]  
KIDD KK, 1977, HLA DISEASE
[7]   A MONOSPECIFIC HLA-B27 FLUORESCEIN ISOTHIOCYANATE-CONJUGATED MONOCLONAL-ANTIBODY FOR RAPID, SIMPLE AND ACCURATE HLA-B27 TYPING [J].
PEI, R ;
ARJOMANDSHAMSAI, M ;
DENG, CT ;
CESBRON, A ;
BIGNON, JD ;
LEE, JH .
TISSUE ANTIGENS, 1993, 41 (04) :200-203
[8]   MICRODROPLET ASSAY OF HUMAN SERUM CYTOTOXINS [J].
TERASAKI, PI ;
MCCLELLAND, JD .
NATURE, 1964, 204 (496) :998-&
[9]  
ZACHARY AA, 1990, AM SOC HISTOCOMPATIB