A DETERMINATION OF THE REGIONAL BRAIN BLOOD PARTITION-COEFFICIENT OF WATER USING DYNAMIC POSITRON EMISSION TOMOGRAPHY

被引:75
作者
IIDA, H
KANNO, I
MIURA, S
MURAKAMI, M
TAKAHASHI, K
UEMURA, K
机构
关键词
D O I
10.1038/jcbfm.1989.121
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:874 / 885
页数:12
相关论文
共 35 条
  • [11] QUANTITATION IN POSITRON EMISSION TOMOGRAPHY .8. EFFECTS OF NONLINEAR PARAMETER-ESTIMATION ON FUNCTIONAL IMAGES
    HUANG, SC
    MAHONEY, DK
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (02) : 314 - 325
  • [12] MEASUREMENT OF LOCAL BLOOD-FLOW AND DISTRIBUTION VOLUME WITH SHORT-LIVED ISOTOPES - A GENERAL INPUT TECHNIQUE
    HUANG, SC
    CARSON, RE
    PHELPS, ME
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1982, 2 (01) : 99 - 108
  • [13] ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION
    IIDA, H
    KANNO, I
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    UEMURA, K
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05) : 536 - 545
  • [14] MEASUREMENT OF ABSOLUTE MYOCARDIAL BLOOD-FLOW WITH (H2O)-O-15 AND DYNAMIC POSITRON-EMISSION TOMOGRAPHY - STRATEGY FOR QUANTIFICATION IN RELATION TO THE PARTIAL-VOLUME EFFECT
    IIDA, H
    KANNO, I
    TAKAHASHI, A
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    ONO, Y
    SHISHIDO, F
    INUGAMI, A
    TOMURA, N
    HIGANO, S
    FUJITA, H
    SASAKI, H
    NAKAMICHI, H
    MIZUSAWA, S
    KONDO, Y
    UEMURA, K
    [J]. CIRCULATION, 1988, 78 (01) : 104 - 115
  • [15] EVALUATION OF REGIONAL DIFFERENCES OF TRACER APPEARANCE TIME IN CEREBRAL TISSUES USING [O-15]WATER AND DYNAMIC POSITRON EMISSION TOMOGRAPHY
    IIDA, H
    HIGANO, S
    TOMURA, N
    SHISHIDO, F
    KANNO, I
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    SASAKI, H
    UEMURA, K
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (02) : 285 - 288
  • [16] IIDA H, 1988, Journal of Nuclear Medicine, V29, P867
  • [17] ERROR ANALYSIS FOR THE DETERMINATION OF CEREBRAL BLOOD-FLOW WITH THE CONTINUOUS INHALATION OF O-15-LABELED CARBON-DIOXIDE AND POSITRON EMISSION TOMOGRAPHY
    JONES, SC
    GREENBERG, JH
    REIVICH, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (01) : 116 - 124
  • [18] MEASUREMENT OF CEREBRAL BLOOD-FLOW USING BOLUS INHALATION OF (CO2)-O-15 AND POSITRON EMISSION TOMOGRAPHY - DESCRIPTION OF THE METHOD AND ITS COMPARISON WITH THE (CO2)-O-15 CONTINUOUS INHALATION METHOD
    KANNO, I
    LAMMERTSMA, AA
    HEATHER, JD
    GIBBS, JM
    RHODES, CG
    CLARK, JC
    JONES, T
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (02) : 224 - 234
  • [19] DESIGN AND EVALUATION OF A POSITRON EMISSION TOMOGRAPH - HEADTOME-III
    KANNO, I
    MIURA, S
    YAMAMOTO, S
    IIDA, H
    MURAKAMI, M
    TAKAHASHI, K
    UEMURA, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (05) : 931 - 939
  • [20] A SYSTEM FOR CEREBRAL BLOOD-FLOW MEASUREMENT USING AN (H2O)-O-15 AUTORADIOGRAPHIC METHOD AND POSITRON EMISSION TOMOGRAPHY
    KANNO, I
    IIDA, H
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    SASAKI, H
    INUGAMI, A
    SHISHIDO, F
    UEMURA, K
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (02) : 143 - 153