ISOTOPE-RATIO-MONITORING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY - METHODS FOR ISOTOPIC CALIBRATION

被引:105
作者
MERRITT, DA
BRAND, WA
HAYES, JM
机构
[1] INDIANA UNIV,DEPT CHEM,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
[2] INDIANA UNIV,DEPT GEOL SCI,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
[3] FINNIGAN MAT CORP,W-2800 BREMEN,GERMANY
关键词
C-13; ISOTOPE RATIO; MASS SPECTROMETRY; ANALYSIS;
D O I
10.1016/0146-6380(94)90003-5
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
In trial analyses of a series of n-alkanes, precise determinations of C-13 contents were based on isotopic standards introduced by five different techniques and results were compared. Specifically, organic-compound standards were coinjected with the analytes and carried through chromatography and combustion with them; or CO2 was supplied from a conventional inlet and mixed with the analyte in the ion source, or CO2 was supplied from an auxiliary mixing volume and transmitted to the source without interruption of the analyte stream. Additionally, two techniques were investigated in which the analyte stream was diverted and CO2 standards were placed on a near-zero background. All methods provided accurate results. Where applicable, methods not involving interruption of the analyte stream provided the highest performance (sigma = 0.00006 at.% C-13 or 0.06 parts per thousand for 250 pmol C as CO2 reaching the ion source), but great care was required. Techniques involving diversion of the analyte stream were immune to interference from coeluting sample components and still provided high precision (0.0001 less-than-or-equal-to sigma less-than-or-equal-to 0.0002 at. % or 0.1 less-than-or-equal-to or less-than-or-equal-to 0.2 parts per thousand).
引用
收藏
页码:573 / 583
页数:11
相关论文
共 9 条
[1]   GAS-CHROMATOGRAPHY - STABLE ISOTOPE RATIO ANALYSIS AT NATURAL ABUNDANCE LEVELS [J].
BARRIE, A ;
BRICOUT, J ;
KOZIET, J .
BIOMEDICAL MASS SPECTROMETRY, 1984, 11 (11) :583-588
[2]  
COLLISTER JW, 1992, THESIS INDIANA U BLO
[3]  
FRAZER JW, 1963, MIKROCHIM ACTA, P561
[4]  
FREEDMAN PA, 1988, AM LAB, V20, P114
[5]   COMPOUND-SPECIFIC ISOTOPIC ANALYSES - A NOVEL TOOL FOR RECONSTRUCTION OF ANCIENT BIOGEOCHEMICAL PROCESSES [J].
HAYES, JM ;
FREEMAN, KH ;
POPP, BN ;
HOHAM, CH .
ORGANIC GEOCHEMISTRY, 1990, 16 (4-6) :1115-1128
[6]   ENHANCED RESOLUTION OF ORGANIC-COMPOUNDS FROM SEDIMENTS BY ISOTOPIC GAS-CHROMATOGRAPHY COMBUSTION MASS-SPECTROMETRY [J].
LICHTFOUSE, E ;
FREEMAN, KH ;
COLLISTER, JW ;
MERRITT, DA .
JOURNAL OF CHROMATOGRAPHY, 1991, 585 (01) :177-180
[7]  
MERRITT DA, 1994, UNPUB ANAL CHEM
[8]   ACQUISITION AND PROCESSING OF DATA FOR ISOTOPE-RATIO-MONITORING MASS-SPECTROMETRY [J].
RICCI, MP ;
MERRITT, DA ;
FREEMAN, KH ;
HAYES, JM .
ORGANIC GEOCHEMISTRY, 1994, 21 (6-7) :561-571
[9]   ISOTOPIC ANALYSES BASED ON THE MASS-SPECTRUM OF CARBON-DIOXIDE [J].
SANTROCK, J ;
STUDLEY, SA ;
HAYES, JM .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1444-1448