AMPEROMETRIC ENZYME SENSOR FOR GLUCOSE BASED ON GRAPHITE PASTE-MODIFIED ELECTRODES

被引:41
作者
PANDEY, PC
KAYASTHA, AM
PANDEY, V
机构
[1] Department of Chemistry, Banaras Hindu University, Varanasi
关键词
ENZYME ELECTRODE; HYDRODYNAMIC AMPEROMETRY; PLASMA ANALYSIS;
D O I
10.1007/BF02950782
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Amperometric enzyme electrode for glucose is described based on the incorporation of glucose oxidase (GOD) into graphite paste modified with tetracyanoquinodimethane (TCNQ). The incorporated enzyme exhibits high activity and long-term stability over the earlier TCNQ-based glucose sensor (1). The sensor provides a linear response to glucose over a wide concentration range. The response time of the sensor is 15-50 sec, and the detection limit is 0.5 mM. Stable response to the substrate was obtained during a period of 35 d. Application of the sensor in the plasma analysis is reported.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 19 条
[1]   ELECTROCHEMICAL SENSORS - THEORY AND EXPERIMENT [J].
ALBERY, WJ ;
BARTLETT, PN ;
CASS, AEG ;
CRASTON, DH ;
HAGGETT, BGD .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1033-1050
[2]   AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ .
TALANTA, 1991, 38 (01) :107-110
[3]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[4]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[5]   BIOCATALYTIC OXIDATION OF GLUCOSE ON THE CONDUCTIVE CHARGE-TRANSFER COMPLEXES [J].
CENAS, NK ;
KULYS, JJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1981, 8 (01) :103-113
[6]  
CENAS NK, 1981, J ELECTROANAL CHEM, V128, P103
[7]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289
[8]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[9]  
Guilbault G., 1984, ANAL USES IMMOBILIZE
[10]  
GUILBAULT GG, 1987, BIOTECHNOL APPL BIOC, V9, P95