A RATIO PULSE-SHAPE DISCRIMINATOR

被引:5
作者
HE, Z
BIRD, AJ
RAMSDEN, D
机构
[1] Physics Department, University of Southampton, Southampton
关键词
D O I
10.1016/0168-9002(93)91104-U
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A simple pulse-shape discriminator has been designed to separate signals from a CsI(Na)/GSO phoswich detector. It Can provide information on both the total energy deposited and the contribution of each crystal to that total, allowing a software veto to be used according to the distribution of the energy deposited. Test results show that even for photons having an energy of 17 keV, the location of most of the interactions can be found unambiguously. The system has also been tested on the most commonly used NaI(Tl)/CsI(Tl) phoswich detector without particular optimisation of the shaping time-constants. These results show that it can work well for gamma-rays below 17 keV. This technique could be very useful in a system which produces more than two decay components, such as a triple phoswich detector, or in a system where pulse-shape discrimination is used for particle identification.
引用
收藏
页码:236 / 245
页数:10
相关论文
共 13 条
[1]   VERSATILE PULSE SHAPE DISCRIMINATOR FOR CHARGED-PARTICLE SEPARATION AND ITS APPLICATION TO FAST-NEUTRON TIME-OF-FLIGHT SPECTROSCOPY [J].
ADAMS, JM ;
WHITE, G .
NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (03) :459-476
[2]   PULSE SHAPE-DISCRIMINATION WITH A 100 MHZ FLASH ADC SYSTEM [J].
ALEKSAN, R ;
BOUCHEZ, J ;
BOUSSICUT, M ;
DESANLIS, T ;
JOURDE, D ;
MULLIE, J ;
PIERRE, F ;
POINSIGNON, L ;
PRACA, R ;
ROUSSEL, G ;
THOMAS, JF ;
COLLOT, J ;
STUTZ, A ;
KAJFASZ, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01) :303-309
[3]   STUDY OF (N,P) AND (N,ALPHA) REACTIONS IN NAI(TL) USING A PULSE-SHAPE-DISCRIMINATION METHOD [J].
BARTLE, CM .
NUCLEAR INSTRUMENTS & METHODS, 1975, 124 (02) :547-550
[4]   A SCINTILLATION COUNTER WITH NEUTRON AND GAMMA-RAY DISCRIMINATORS [J].
BROOKS, FD .
NUCLEAR INSTRUMENTS & METHODS, 1959, 4 (03) :151-163
[5]   LOW-ENERGY PERFORMANCE OF MUNICH PSD SYSTEM [J].
CHALUPKA, A ;
STENGL, G ;
MAIER, MR ;
SPERR, P .
NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (02) :209-211
[6]   A RATIO PULSE-SHAPE DISCRIMINATOR [J].
HE, Z ;
BIRD, AJ ;
RAMSDEN, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2) :236-245
[7]   PARTICLE IDENTIFICATION VIA PULSE-SHAPE DISCRIMINATION WITH A CHARGE-INTEGRATING ADC [J].
HELTSLEY, JH ;
BRANDON, L ;
GALONSKY, A ;
HEILBRONN, L ;
REMINGTON, BA ;
LANGER, S ;
VANDERMOLEN, A ;
YURKON, J ;
KASAGI, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (2-3) :441-445
[8]   POSITION-SENSITIVE PHOTOMULTIPLIER TUBES FOR SCINTILLATION IMAGING [J].
KUME, H ;
MURAMATSU, S ;
IIDA, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :359-363
[9]   ON IMPROVING GE DETECTOR ENERGY RESOLUTION AND PEAK-TO-COMPTON RATIOS BY PULSE-SHAPE DISCRIMINATION [J].
MATSUSHITA, N ;
MCHARRIS, WC ;
FIRESTONE, RB ;
KASAGI, J ;
KELLY, WH .
NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (01) :119-124
[10]   ORGANIC-SCINTILLATOR PULSE-SHAPE DISCRIMINATOR SIGNATURES ASSOCIATED WITH HIGH-ENERGY NEUTRONS [J].
ONGE, RS ;
GALONSKY, A ;
JOLLY, RK ;
AMOS, TM .
NUCLEAR INSTRUMENTS & METHODS, 1975, 126 (03) :391-395