ENDOCARDIAL PACING, CARDIOVERSION AND DEFIBRILLATION USING A BRAIDED ENDOCARDIAL LEAD SYSTEM

被引:21
作者
SAKSENA, S
LUCERI, R
KROL, RB
BROWNSTEIN, S
BURKHARDT, E
ACCORTI, P
BREWER, G
SCOTT, S
CALLAGHAN, F
LIVINGSTON, A
机构
[1] UNIV MED & DENT NEW JERSEY,NEW JERSEY MED SCH,NEWARK,NJ 07103
[2] HOLY CROSS HOSP,FT LAUDERDALE,FL
[3] TELECTRON PACING SYST INC,MIAMI,FL
关键词
D O I
10.1016/0002-9149(93)90833-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The clinical efficacy and safety of a second-generation braided endocardial pacing, cardioversion and defibrillation lead system was evaluated in 25 patients with ventricular tachycardia (VT) or ventricular fibrillation (VF). The lead system consisted of two 8Fr active fixation endocardial leads each with pacing and defibrillation electrodes and a thoracic patch electrode. Monophasic and biphasic shocks were delivered using a triple-electrode configuration with a right ventricular common cathode and right atrial and thoracic patch anodes. VT and VF were electrically induced. Rapid VT (rate greater-than-or-equal-to 180 beats/min) and VF were initially terminated by 20 J (550 V) shocks and slow VT (rate < 180 beats/min) by 10 J (400 V) shocks. One hundred fourteen episodes (rapid VT/VF 73, slow VT 41) were treated with 128 shocks (monophasic 80, biphasic 48). Mean ventricular pacing threshold was 0.7 +/- 0.5 ms before and 0.9 +/- 0.5 ms after endocardial shock delivery (p >0.2). Mean ventricular electrogram amplitude in sinus rhythm was 11.9 +/- 5.7 mV before and 11.4 +/- 5.1 mV after shock delivery (p > 0.2). Simultaneous monophasic endocardial shocks terminated 53% of VF episodes at less-than-or-equal-to 20 J. Simultaneous biphasic shocks terminated 94% of all VF episodes at less-than-or-equal-to 20 J (p < 0.03). Efficacy of greater-than-or-equal-to 10 J shocks for rapid VT/VF was greater for biphasic (92%) versus monophasic (74%) shocks (p < 0.05) at lower average shock energy (15 +/- 7 J vs 19 +/- 7 J, respectively, p < 0.05). Logistic regression analysis demonstrated that mean voltage for 80% success for arrhythmia conversion was significantly uniformly lower (p less-than-or-equal-to 0.002) for biphasic than for monophasic shocks in slow VT, fast VT and VF. With use of this model, biphasic shocks were more effective than monophasic shocks over all voltage ranges tested in induced VT and VF. Total measured shock impedance was comparable for biphasic and monophasic shocks (p greater-than-or-equal-to 0.2). Peak-to-peak digitized unfiltered ventricular electrogram amplitude during induced VT did not differ significantly from sinus rhythm (p greater-than-or-equal-to 0.2) but did decline in VF to 10.6 +/- 4.2 mV (p < 0.05). It is concluded that VT and VF termination can be safely achieved in humans with endocardial shocks using a triple-electrode configuration with this second-generation lead system. Simultaneous biphasic shocks increase success rates and lower endocardial cardioversion/defibrillation energy requirements in rapid VT/VF and are safe for clinical application.
引用
收藏
页码:834 / 841
页数:8
相关论文
共 25 条
[1]   COMPARATIVE SURVIVAL AFTER PERMANENT VENTRICULAR AND DUAL CHAMBER PACING FOR PATIENTS WITH CHRONIC HIGH DEGREE ATRIOVENTRICULAR-BLOCK WITH AND WITHOUT PREEXISTENT CONGESTIVE-HEART-FAILURE [J].
ALPERT, MA ;
CURTIS, JJ ;
SANFELIPPO, JF ;
FLAKER, GC ;
WALLS, JT ;
MUKERJI, V ;
VILLARREAL, D ;
KATTI, SK ;
MADIGAN, NP ;
KROL, RB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) :925-932
[2]   SURVIVAL IN PATIENTS WITH DEPRESSED LEFT-VENTRICULAR FUNCTION TREATED BY IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
AXTELL, K ;
TCHOU, P ;
AKHTAR, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :291-296
[3]   TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS [J].
BARDY, GH ;
ALLEN, MD ;
MEHRA, R ;
JOHNSON, G ;
FELDMAN, S ;
GREENE, HL ;
IVEY, TD .
CIRCULATION, 1990, 81 (04) :1252-1259
[4]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[5]   ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
TROUTMAN, C ;
JOHNSON, G ;
MEHRA, R ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
GARTMAN, DM .
CIRCULATION, 1991, 84 (02) :665-671
[6]   A PROSPECTIVE RANDOMIZED STUDY OF THE CLINICAL EFFICACY AND SAFETY OF TRANSVENOUS CARDIOVERSION FOR TERMINATION OF VENTRICULAR-TACHYCARDIA [J].
CICCONE, JM ;
SAKSENA, S ;
SHAH, Y ;
PANTOPOULOS, D .
CIRCULATION, 1985, 71 (03) :571-578
[7]   DECREASED DEFIBRILLATOR-INDUCED DYSFUNCTION WITH BIPHASIC RECTANGULAR WAVEFORMS [J].
JONES, JL ;
JONES, RE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (05) :H792-H796
[8]   PROSPECTIVE EVALUATION OF A SEQUENTIAL PACING AND HIGH-ENERGY BIDIRECTIONAL SHOCK ALGORITHM FOR TRANSVENOUS CARDIOVERSION IN PATIENTS WITH VENTRICULAR-TACHYCARDIA [J].
LINDSAY, BD ;
SAKSENA, S ;
ROTHBART, ST ;
WASTY, N ;
PANTOPOULOS, D .
CIRCULATION, 1987, 76 (03) :601-609
[9]   FEASIBILITY AND EFFECTIVENESS OF LOW-ENERGY CATHETER DEFIBRILLATION IN MAN [J].
MIROWSKI, M ;
MOWER, MM ;
GOTT, VL ;
BRAWLEY, RK .
CIRCULATION, 1973, 47 (01) :79-85
[10]  
REYNOLDS DW, 1983, PACE, V6, pA80