ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS

被引:55
作者
BARDY, GH
TROUTMAN, C
JOHNSON, G
MEHRA, R
POOLE, JE
DOLACK, GL
KUDENCHUK, PJ
GARTMAN, DM
机构
[1] UNIV WASHINGTON,DEPT MED,DIV CARDIOTHORAC SURG,SEATTLE,WA 98195
[2] UNIV WASHINGTON,DEPT SURG,SEATTLE,WA 98195
关键词
VENTRICULAR FIBRILLATION; BIPHASIC WAVE-FORM; AUTOMATIC CARDIOVERTER-DEFIBRILLATOR; SUDDEN DEATH;
D O I
10.1161/01.CIR.84.2.665
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed for two distinct nonthoracotomy lead systems as well as for an epicardial electrode system in 51 cardiac arrest survivors undergoing automatic defibrillator implantation. Methods and Results. The configurations tested consisted of a right ventricular-left ventricular (RV-LV) epicardial patch-patch system, an RV catheter-chest patch (CP) nonthoracotomy system, and a coronary sinus (CS) catheter-RV catheter nonthoracotomy system. For each configuration, the defibrillation current and voltage waveforms were recorded via a digital oscilloscope to measure defibrillation threshold voltage, current, resistance, and stored energy. Biphasic waveform defibrillation proved more efficient than monophasic waveform defibrillation for the epicardial RV-LV system (4.8 +/- 4.1 versus 6.7 +/- 4.9 J, p = 0.047) and the nonthoracotomy RV-CP system (23.4 +/- 11.1 versus 34.3 +/- 10.4 J, p = 0.0042). Biphasic waveform defibrillation thresholds were not significantly lower than monophasic waveform defibrillation thresholds for the CS-RV nonthoracotomy system (15.6 +/- 7.2 versus 20.0 +/- 11.5 J, p = 0.11). Biphasic waveform defibrillation proved more efficacious than monophasic waveform defibrillation in 13 of 20 patients (65%) with RV-LV epicardial patches, 10 of 15 patients (67%) with an RV-CP nonthoracotomy system, and nine of 16 patients (56%) with an RV-CS nonthoracotomy system. Conclusions. Biphasic pulsing was useful with nonthoracotomy lead systems as well as with epicardial lead systems. However, the degree of biphasic waveform defibrillation superiority appeared to be electrode system dependent. Furthermore, for a few individuals, biphasic waveform defibrillation proved less efficient than monophasic waveform defibrillation, regardless of the lead system used.
引用
收藏
页码:665 / 671
页数:7
相关论文
共 24 条
  • [1] A PROSPECTIVE, RANDOMIZED EVALUATION OF EFFECT OF VENTRICULAR-FIBRILLATION DURATION ON DEFIBRILLATION THRESHOLDS IN HUMANS
    BARDY, GH
    IVEY, TD
    ALLEN, M
    JOHNSON, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) : 1362 - 1366
  • [2] EVALUATION OF ELECTRODE POLARITY ON DEFIBRILLATION EFFICACY
    BARDY, GH
    IVEY, TD
    ALLEN, MD
    JOHNSON, G
    GREENE, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (07) : 433 - 437
  • [3] TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    FELDMAN, S
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION, 1990, 81 (04) : 1252 - 1259
  • [4] A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS
    BARDY, GH
    IVEY, TD
    ALLEN, MD
    JOHNSON, G
    MEHRA, R
    GREENE, HL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 728 - 733
  • [5] AN EFFECTIVE AND ADAPTABLE TRANSVENOUS DEFIBRILLATION SYSTEM USING THE CORONARY SINUS IN HUMANS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) : 887 - 895
  • [6] PROSPECTIVE COMPARISON OF SEQUENTIAL PULSE AND SINGLE PULSE DEFIBRILLATION WITH USE OF 2 DIFFERENT CLINICALLY AVAILABLE SYSTEMS
    BARDY, GH
    IVEY, TD
    ALLEN, MD
    JOHNSON, G
    GREENE, HL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (01) : 165 - 171
  • [7] SENSITIVITY OF CALCIUM-BINDING IN CEREBRAL TISSUE TO WEAK ENVIRONMENTAL ELECTRIC-FIELDS OSCILLATING AT LOW-FREQUENCY
    BAWIN, SM
    ADEY, WR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1976, 73 (06) : 1999 - 2003
  • [8] BELTRAME F, 1980, ALTA FREQ, V49, P101
  • [9] COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY
    CHEN, PS
    SHIBATA, N
    DIXON, EG
    MARTIN, RO
    IDEKER, RE
    [J]. CIRCULATION, 1986, 73 (05) : 1022 - 1028
  • [10] IMPROVED DEFIBRILLATION THRESHOLDS WITH LARGE CONTOURED EPICARDIAL ELECTRODES AND BIPHASIC WAVE-FORMS
    DIXON, EG
    TANG, ASL
    WOLF, PD
    MEADOR, JT
    FINE, MJ
    CALFEE, RV
    IDEKER, RE
    [J]. CIRCULATION, 1987, 76 (05) : 1176 - 1184