THE EFFECTS OF AGE AND GENDER ON BRACHIAL-ARTERY ENDOTHELIUM-DEPENDENT VASOACTIVITY ARE STIMULUS-DEPENDENT

被引:49
作者
CORRETTI, MC [1 ]
PLOTNICK, GD [1 ]
VOGEL, RA [1 ]
机构
[1] UNIV MARYLAND, SCH MED, DEPT MED, DIV CARDIOL, BALTIMORE, MD 21201 USA
关键词
ENDOTHELIUM; ULTRASOUND; VASOACTIVITY; AGE; OLD PRESSER;
D O I
10.1002/clc.4960180810
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Impaired endothelium-dependent vasomotion in response to flow-mediated, cholinergic, and cold presser stimulation has been demonstrated in the presence of both atherosclerosis and cardiac risk factors. This study investigated the effects of different vasoactive stimuli on brachial artery vasomotion with respect to age and gender. Forty healthy subjects (20 men and 20 women), ages 23 to 52 years, were studied. Using 7.5 MHz ultrasound, brachial artery diameter and Doppler flow velocity at baseline, following 5 min of ipsilateral blood pressure cuff occlusion (flow-mediated), during contralateral hand immersion in ice (cold presser) and after sublingual nitroglycerin administration, were measured in older subjects (> 40 yrs) and younger subjects (< 40 yrs). Among normal subjects, % diameter change in response to the flow-mediated stimulus was less in older men than in younger men (6.8 +/- 3.2% vs. 11.5 +/- 7.4%, p < 0.05); older and younger women had comparable responses (10.0 +/- 5.3% vs. 11.6 +/- 4.3%, p = NS). With cold presser, normal alder men and older women vasoconstricted (-1.2 +/- 0.9%, -2.2 +/- 4.7%) compared with younger subjects who vasodilated (1.4 +/- 2.5%, 0.6 +/- 2.3%, p<0.02). The cold presser test elicited comparable responses among older normal subjects. Nitroglycerin, a non-endothelium-mediated stimulus, induced significant vasodilatation in all the groups. In conclusion, endothelium-mediated responses in subjects of varying age and gender are stimulus-dependent. Flow-mediated vasodilatation could not differentiate older premenopausal women from younger women; cold presser stimulus could.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 36 条
[21]   DILATION OF NORMAL AND CONSTRICTION OF ATHEROSCLEROTIC CORONARY-ARTERIES CAUSED BY THE COLD PRESSOR TEST [J].
NABEL, EG ;
GANZ, P ;
GORDON, JB ;
ALEXANDER, RW ;
SELWYN, AP .
CIRCULATION, 1988, 77 (01) :43-52
[22]   RESPONSE OF ANGIOGRAPHICALLY NORMAL AND ATHEROSCLEROTIC LEFT ANTERIOR DESCENDING CORONARY-ARTERIES TO ACETYLCHOLINE [J].
NEWMAN, CM ;
MASERI, A ;
HACKETT, DR ;
ELTAMIMI, HM ;
DAVIES, GJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) :1070-1076
[23]  
Nitenberg Alain, 1993, Journal of the American College of Cardiology, V21, p65A
[24]   EVIDENCE THAT SELECTIVE ENDOTHELIAL DYSFUNCTION MAY OCCUR IN THE ABSENCE OF ANGIOGRAPHIC OR ULTRASOUND ATHEROSCLEROSIS IN PATIENTS WITH RISK-FACTORS FOR ATHEROSCLEROSIS [J].
REDDY, KG ;
NAIR, RN ;
SHEEHAN, HM ;
HODGSON, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (04) :833-843
[25]   FLOW-INDUCED RELEASE OF ENDOTHELIUM-DERIVED RELAXING FACTOR [J].
RUBANYI, GM ;
ROMERO, JC ;
VANHOUTTE, PM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (06) :1145-1149
[26]   INFLUENCE OF SERUM-CHOLESTEROL AND OTHER CORONARY RISK-FACTORS ON VASOMOTION OF ANGIOGRAPHICALLY NORMAL CORONARY-ARTERIES [J].
SEILER, C ;
HESS, OM ;
BUECHI, M ;
SUTER, TM ;
KRAYENBUEHL, HP .
CIRCULATION, 1993, 88 (05) :2139-2148
[27]  
TESFAMARIAN B, 1993, CIRC RES, V63, P720
[28]  
UEHATA A, 1993, CIRCULATION, V88, P618
[29]  
VALLANCE P, 1989, LANCET, V2, P997
[30]   CORONARY VASOMOTOR RESPONSE TO ACETYLCHOLINE RELATES TO RISK-FACTORS FOR CORONARY-ARTERY DISEASE [J].
VITA, JA ;
TREASURE, CB ;
NABEL, EG ;
MCLENACHAN, JM ;
FISH, RD ;
YEUNG, AC ;
VEKSHTEIN, VI ;
SELWYN, AP ;
GANZ, P .
CIRCULATION, 1990, 81 (02) :491-497