THE DIAGNOSTIC-ACCURACY OF DUPLEX ULTRASONOGRAPHY FOR EVALUATING CAROTID BIFURCATION

被引:17
作者
BALLARD, JL [1 ]
FLEIG, K [1 ]
DELANGE, M [1 ]
KILLEEN, JD [1 ]
机构
[1] LOMA LINDA UNIV,MED CTR,DEPT DIAGNOST ULTRASOUND,LOMA LINDA,CA
关键词
D O I
10.1016/S0002-9610(94)80050-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: In many medical centers the standard preoperative study for patients under-going carotid endarterectomy is four-vessel carotid arteriography, but duplex scanning of the carotid bifurcation is also reported to be highly accurate for detecting stenotic or occluded carotid arteries. METHODS: The diagnostic accuracy of duplex ultrasonography was evaluated in a study of 774 carotid bifurcations, in 400 patients comparing the degree of predicted internal carotid artery (ICA) stenosis found using that technique, with that found by contrast arteriography. Agreement between the predicted degree of ICA stenosis and the arteriographic measurement was evaluated using the Spearman rank order correlation. Accuracy statistics for duplex scanning as a diagnostic modality were assessed using 2 x 2 tables. RESULTS: The Spearman rank order correlation coefficient was 0.74 (p = 0) for the symptomatic group, 0.65 (P = 0) for the asymptomatic group, and 0.68 (P = 0) for the total group. The accuracy of duplex ultrasonography for detecting all grades of ICA stenosis ranged from 80% to 97%. CONCLUSIONS: Duplex ultrasonography of the carotid bifurcation is a reliable diagnostic tool and can be used as the sole preoperative study for selected patients with extracranial cerebrovascular disease. Our current algorithm is discussed in conjunction with a critical analysis of this large database.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 18 条
[1]   THE ASSESSMENT OF CAROTID AND VERTEBRAL ARTERIES - A COMPARISON OF CFM DUPLEX ULTRASOUND WITH INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY [J].
COLQUHOUN, I ;
OATES, CP ;
MARTIN, K ;
HALL, K ;
WHITTINGHAM, TA .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (780) :1069-1074
[2]   ROLE OF ARTERIOGRAPHY IN THE PREOPERATIVE EVALUATION OF CAROTID-ARTERY DISEASE [J].
DAWSON, DL ;
ZIERLER, RE ;
KOHLER, TR .
AMERICAN JOURNAL OF SURGERY, 1991, 161 (05) :619-624
[3]  
GELABERT HA, 1990, SURG CLIN N AM, V70, P213
[4]  
Hill J C, 1990, Ann Vasc Surg, V4, P34, DOI 10.1007/BF02042686
[5]   IDENTIFYING TOTAL CAROTID OCCLUSION WITH COLOR FLOW DUPLEX SCANNING [J].
MATTOS, MA ;
HODGSON, KJ ;
RAMSEY, DE ;
BARKMEIER, LD ;
SUMNER, DS .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (02) :204-210
[6]  
McKittrick J E, 1993, Ann Vasc Surg, V7, P311, DOI 10.1007/BF02002880
[7]   CAN CLINICAL-EVALUATION AND NONINVASIVE TESTING SUBSTITUTE FOR ARTERIOGRAPHY IN THE EVALUATION OF CAROTID-ARTERY DISEASE [J].
MOORE, WS ;
ZIOMEK, S ;
QUINONESBALDRICH, WJ ;
MACHLEDER, HI ;
BUSUTTIL, RW ;
BAKER, JD .
ANNALS OF SURGERY, 1988, 208 (01) :91-94
[8]  
POINDEXTER JM, 1991, J CARDIOVASC SURG, V32, P64
[9]   INTERNAL CAROTID-ARTERY STENOSIS - ACCURACY AND REPRODUCIBILITY OF COLOR-DOPPLER-ASSISTED DUPLEX IMAGING [J].
POLAK, JF ;
DOBKIN, GR ;
OLEARY, DH ;
WANG, AM ;
CUTLER, SS .
RADIOLOGY, 1989, 173 (03) :793-798
[10]   DETECTION OF INTERNAL CAROTID-ARTERY STENOSIS - COMPARISON OF MR ANGIOGRAPHY, COLOR DOPPLER SONOGRAPHY, AND ARTERIOGRAPHY [J].
POLAK, JF ;
BAJAKIAN, RL ;
OLEARY, DH ;
ANDERSON, MR ;
DONALDSON, MC ;
JOLESZ, FA .
RADIOLOGY, 1992, 182 (01) :35-40