A MONO ISOCENTRIC TECHNIQUE FOR BREAST AND REGIONAL NODAL THERAPY USING DUAL ASYMMETRIC JAWS

被引:44
作者
KLEIN, EE [1 ]
TAYLOR, M [1 ]
MICHALETZLORENZ, M [1 ]
ZOELLER, D [1 ]
UMFLEET, W [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 28卷 / 03期
关键词
BREAST; FIELD MATCHING; ASYMMETRIC JAWS; TREATMENT TECHNIQUES;
D O I
10.1016/0360-3016(94)90204-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Definitive radiation therapy for breast cancer with regional nodal involvement often introduces treatment of adjacent abutted regions. Many methods describe techniques to achieve an effective transverse plane match. Our facility recently adopted a matching technique using asymmetric jaws to beam-split all portals along the central axis plane. Our technique uses one isocenter to treat the opposed tangential breast fields, the supraclavicular port and the posterior axillary field. Methods and Materials: Our linear accelerator has four collimator jaws capable of being set independently. The longitudinal (Y) jaws beam-split all the portals at the match plane, namely the upper border of the tangential beams and the bottom border of the nodal fields. The transverse (X) jaws define the lateral borders of the nodal fields, and in a near beam-split fashion in conjunction with customized Cerrobend, block the lung for the tangential beams. The unique isocenter is chosen along the mid-bridge through the tangential match plane. Dosimetric qualities and calculational techniques of the asymmetric beams were analyzed with ionimetric water scans, ion chamber studies, and film. The match-line is clinically confirmed with composite port films. Results: Our dosimetric studies show asymmetric jaws provide nearly equivalent field edge definition and superior absorption in comparison with Cerrobend blocks. The use of one isocenter results in a reduction of in-room treatment time by a factor of two. The burden of lifting heavy Cerrobend blocks has been removed. A composite port film, which includes the medial tangential and supraclavicular ports, shows a perfect match-line in all cases. Similar composite port films taken with our previous technique of geometric matching with collimator and table angulation exhibit slight overlap or underdose regions in many cases. Conclusion: Our treatment technique takes full advantage of dual asymmetric jaws to achieve a perfect match-line, necessitates only one isocenter and set-up point, and supplies more absorption in reference to lung and contralateral breast dose. The pure match-line is accompanied by the fact that the patient does not have to move in any direction.
引用
收藏
页码:753 / 760
页数:8
相关论文
共 18 条
[1]   A NONDIVERGENT 3 FIELD MATCHING TECHNIQUE FOR BREAST IRRADIATION [J].
CHU, JCH ;
SOLIN, LJ ;
HWANG, CC ;
FOWBLE, B ;
HANKS, GE ;
GOODMAN, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1037-1040
[2]   3-FIELD ISOCENTRIC TECHNIQUE FOR BREAST IRRADIATION USING INDIVIDUALIZED SHIELDING BLOCKS [J].
CONTE, G ;
NASCIMBEN, O ;
TURCATO, G ;
POLICO, R ;
IDI, MB ;
BELLERI, LM ;
BERGOGLIO, F ;
SIMONATO, F ;
STEA, L ;
BUGIN, F ;
BORTOT, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1299-1305
[3]   CLINICAL USE OF A MATCH-LINE WEDGE FOR ADJACENT MEGAVOLTAGE RADIATION-FIELD MATCHING [J].
FRAASS, BA ;
TEPPER, JE ;
GLATSTEIN, E ;
VANDEGEIJN, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (02) :209-216
[4]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[5]   MATCHLINE DOSIMETRY OF A 3 FIELD TECHNIQUE FOR BREAST TREATMENT USING COBALT OR 6 MV X-RAYS [J].
HUNT, MA ;
KUTCHER, GJ ;
MARTEL, MK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (07) :1099-1106
[6]   ENTRANCE AND EXIT DOSE REGIONS FOR A CLINAC-2100C [J].
KLEIN, EE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :429-435
[7]   FIELD MATCHING IN BREAST IRRADIATION - AN EXACT SOLUTION TO A GEOMETRICAL PROBLEM [J].
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1986, 5 (01) :47-57
[8]   A TECHNIQUE FOR FIELD MATCHING IN PRIMARY BREAST IRRADIATION [J].
LICHTER, AS ;
FRAASS, BA ;
VANDEGEIJN, J ;
PADIKAL, TN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (02) :263-270
[9]   LONG-TERM RADIATION COMPLICATIONS FOLLOWING CONSERVATIVE SURGERY (CS) AND RADIATION-THERAPY (RT) IN PATIENTS WITH EARLY STAGE BREAST-CANCER [J].
PIERCE, SM ;
RECHT, A ;
LINGOS, TI ;
ABNER, A ;
VICINI, F ;
SILVER, B ;
HERZOG, A ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (05) :915-923
[10]  
PODGORSAK EB, 1984, BRIT J RADIOL, V37, P57