EVALUATION OF RADIATION RECEPTION FACTORS IN A ROTARY KILN USING A MODIFIED MONTE-CARLO SCHEME

被引:10
作者
MURTY, CVS
机构
[1] Chemical Engineering Division, Indian Institute of Chemical Technology, Hyderabad
关键词
D O I
10.1016/0017-9310(93)80071-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Application of the Zone method for the calculation of radiative heat transfer in a rotary kiln is hampered by the nonavailability of the direct exchange area data, essential for the use of the Zone method. Monte-Carlo methods provide a rapid and fairly accurate method of calculating the direct exchange areas in an enclosure and the present study demonstrates the use of a nonstochastic Monte-Carlo procedure for the generation of the exchange area data in a rotary kiln system. The model developed is tested for its accuracy using the data available for the axisymmetric cylindrical system. Exchange areas have been calculated using this model for a wide range of kiln radius-absorption coefficient combinations and percent fills of the solid charge. These data, formulated for conciseness as reception factors, facilitate a rapid evaluation of the radiative interchange in rotary kiln enclosures using the Zone method.
引用
收藏
页码:119 / 133
页数:15
相关论文
共 16 条
[11]  
RICHTER W, 1974, 3RD MEMB C INT FLAM
[12]  
RICHTER W, 1978, JOINT M HEAT TRANSFE
[13]  
Sarofim A., 1965, INT J HEAT MASS TRAN, V8, P1153, DOI [10.1016/0017-9310(65)90141-9, DOI 10.1016/0017-9310(65)90141-9]
[14]   CALCULATION OF RADIATIVE HEAT FLUX IN A CYLINDRICAL FURNACE USING MONTE-CARLO METHOD [J].
STEWARD, FR ;
CANNON, P .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1971, 14 (02) :245-&
[15]  
TANIGUCHI H, 1986, 8TH P INT HEAT TRANS, V2, P757
[16]   AN IMPROVED ZONE METHOD USING MONTE-CARLO TECHNIQUES FOR THE SIMULATION OF RADIATION IN INDUSTRIAL FURNACES [J].
VERCAMMEN, HAJ ;
FROMENT, GF .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (03) :329-337