RELATIONSHIP OF AIRBORNE MICROORGANISMS WITH THE LUNG-FUNCTION AND LEUKOCYTE LEVELS OF WORKERS WITH A HISTORY OF HUMIDIFIER FEVER

被引:34
作者
KATEMAN, E
HEEDERIK, D
PAL, TM
SMEETS, M
SMID, T
SPITTELER, M
机构
[1] UNIV WAGENINGEN,DEPT ENVIRONM & TROP HLTH,POB 238,6700 AE WAGENINGEN,NETHERLANDS
[2] UNIV WAGENINGEN,DEPT AIR POLLUT,WAGENINGEN,NETHERLANDS
[3] AKZO,DEPT MED,EMMEN,NETHERLANDS
关键词
Endotoxins; humidifier fever; leucocytes; lung function;
D O I
10.5271/sjweh.1764
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
An influenza-like illness appeared recently among workers in a plant processing synthetic yarn. A humidifier, a cold-water spraying system, was the suspected cause. Lung function changes over the day and week and changes in blood leucocytes were studied among the workers from the suspected department and two reference populations. Exposure to colony-forming units of bacteria and fungi and to endotoxins was also monitored. The workers from the suspected department had statistically significantly lower lung functions on the first workday of the week than the referents. Their blood leucocytes were also raised statistically significantly. The exposure to fungi, bacteria, and endotoxins differed significantly between the various departments, but the measured levels were low. It was concluded that the observed effects were suggestive of a 'Monday morning fever' type of reaction and that adverse effects occurred at exposure levels lower than those found to date in the literature.
引用
收藏
页码:428 / 433
页数:6
相关论文
共 33 条
[21]   INVESTIGATION OF A RESPIRATORY-DISEASE ASSOCIATED WITH AN AIR-CONDITIONING SYSTEM [J].
PICKERING, CAC ;
MOORE, WKS ;
LACEY, J ;
HOLFORDSTREVENS, VC ;
PEPYS, J .
CLINICAL ALLERGY, 1976, 6 (02) :109-118
[22]  
QUANJER PH, 1983, B EUR PHYSIOPATH RES, V19, P1
[23]   MEASUREMENT OF IGG ANTIBODY AND AIRBORNE ANTIGEN TO CONTROL AN INDUSTRIAL OUTBREAK OF HYPERSENSITIVITY PNEUMONITIS [J].
REED, CE ;
SWANSON, MC ;
LOPEZ, M ;
FORD, AM ;
MAJOR, J ;
WITMER, WB ;
VALDES, TB .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1983, 25 (03) :207-210
[24]   EXTRINSIC ALLERGIC ALVEOLITIS CAUSED BY A COLD WATER HUMIDIFIER [J].
ROBERTSON, AS ;
BURGE, PS ;
WIELAND, GA ;
CARMALT, MHB .
THORAX, 1987, 42 (01) :32-37
[25]   HUMIDIFIER FEVER AND ENDOTOXIN EXPOSURE [J].
RYLANDER, R ;
HAGLIND, P ;
LUNDHOLM, M ;
MATTSBY, I ;
STENQVIST, K .
CLINICAL ALLERGY, 1978, 8 (05) :511-516
[26]  
RYLANDER R, 1989, AM REV RESPIR DIS, V140, P91
[27]  
RYLANDER R, 1983, 7TH P COTT DUST RES, P17
[28]  
RYLANDER R, 1983, AM IND HYG ASSOC J, V42, P811
[29]   ENUMERATION OF VIABLE FUNGI IN OCCUPATIONAL ENVIRONMENTS - A COMPARISON OF SAMPLERS AND MEDIA [J].
SMID, T ;
SCHOKKIN, E ;
BOLEIJ, JSM ;
HEEDERIK, D .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1989, 50 (05) :235-239
[30]  
TERKUILE WM, 1984, STAUB REINHALT LUFT, V44, P211