OBJECTIVE DECISION-MAKING FOLLOWING A PORTAL FILM - THE RESULTS OF A PILOT-STUDY

被引:46
作者
DENHAM, JW
DALLY, MJ
HUNTER, K
WHEAT, J
FAHEY, PP
HAMILTON, CS
机构
[1] UNIV NEWCASTLE, NSW HLTH SERV RES GRP, NEWCASTLE, NSW 2308, AUSTRALIA
[2] UNIV NEWCASTLE, SCH THERAPEUT RADIOGRAPHERS, NEWCASTLE, NSW 2308, AUSTRALIA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 26卷 / 05期
关键词
PORTAL FILM ANALYSIS; RADIOTHERAPY TREATMENT ERRORS; QUALITY ASSURANCE;
D O I
10.1016/0360-3016(93)90503-N
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To discriminate between random and systematic treatment setup errors using portal films. Methods and Materials: A bi-dimensional analytic technique using multiple analyses of variance based on Hotelling's T2 statistics to derive numerical and graphical measures of daily portal film accuracy and precision has been trialed using 88 daily portal films from seven patients' treatment. Results: A demonstration is provided of how a reasonable approximation of random variation from the intended (Simulator) field center, and systematic displacement of the mean position of the portal film centers may be derived from a minimum number of portal films. If a random error as great as 10 mm exists, at least six or seven portal films are considered necessary to reliably detect and quantify the size of a systematic error. Conclusion: Our results suggest that a modest systematic error could go undetected until the end of a 5 or 6 week course of treatment if only one portal film is obtained each week. A greater number of portal films should be performed during the first week of treatment to reduce the frequency of such errors. Efforts to separate and quantify both random and systematic errors in setup are worthwhile and will lead to improvements in outcome at the individual patient level and at a departmental level in the development of quality assurance programs.
引用
收藏
页码:869 / 876
页数:8
相关论文
共 21 条
  • [1] BEL A, 1992, RADIOTHER ONCOL S, V24, P533
  • [2] MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER
    BIJHOLD, J
    LEBESQUE, JV
    HART, AAM
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) : 261 - 271
  • [3] WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS
    BYHARDT, RW
    COX, JD
    HORNBURG, A
    LIERMANN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10): : 881 - 887
  • [4] PRECISION OF DETERMINING COMPLIANCE WITH PRESCRIBED FIELDS FROM CONVENTIONAL PORTAL FILMS
    DUNSCOMBE, PB
    FOX, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (733) : 48 - 52
  • [5] ELGAYAD AAH, 1992, RADIOTHER ONCOL S, V24, P545
  • [6] DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY
    EZZ, A
    MUNRO, P
    PORTER, AT
    BATTISTA, J
    JAFFRAY, DA
    FENSTER, A
    OSBORNE, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 159 - 165
  • [7] GRIFFITHS SE, 1987, INT J RADIAT ONCOL, V13, P1383
  • [8] Hamilton C S, 1991, Clin Oncol (R Coll Radiol), V3, P90, DOI 10.1016/S0936-6555(05)81170-7
  • [9] ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY
    HUIZENGA, H
    LEVENDAG, PC
    DEPORRE, PMZR
    VISSER, AG
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) : 181 - 187
  • [10] REPRODUCIBILITY OF FIELD ALIGNMENT IN RADIATION-THERAPY - A LARGE-SCALE CLINICAL-EXPERIENCE
    KIHLEN, B
    RUDEN, BI
    [J]. ACTA ONCOLOGICA, 1989, 28 (05) : 689 - 692