MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW BY SIMULTANEOUS INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND - VALIDATION IN AN ANIMAL-MODEL

被引:41
作者
CHOU, TM [1 ]
SUDHIR, K [1 ]
IWANAGA, S [1 ]
CHATTERJEE, K [1 ]
YOCK, PG [1 ]
机构
[1] BAKER MED RES INST, ALFRED & BAKER MED UNIT, MELBOURNE, VIC, AUSTRALIA
关键词
D O I
10.1016/0002-8703(94)90474-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We examined the accuracy and feasibility of using simultaneous intracoronary Doppler and two-dimensional (2D) ultrasound imaging in the measurement of volumetric coronary blood flow (CBF). A femoral artery-to-circumflex coronary artery shunt was created in four dogs with tubing that incorporated an in-line transit-time ultrasound (TTU) flow probe. A 2D ultrasound catheter was introduced over a 0.014-inch Doppler guide wire into the circumflex artery with the guide wire tip positioned 2 cm beyond the imaging catheter tip. Cross-sectional area (CSA) and average peak velocity (APV) were recorded. CBF was determined from the previously validated relation CBF = CSA X 0.5 APV and the adjusted measurement formula CBF = CSA X 0.47 APV. Within the 119 measurements made, TTU CBF varied from 31 to 385 ml/min. An excellent correlation was found between 2D/Doppler-derived and TTU CBF with both constants; measurement agreement was improved and bias minimal with the 0.47 constant (slope = 0.9997; r = 0.99: p < 0.0001; SEE = - 6.7 +/- 8.6). We conclude that simultaneous 2D and Doppler ultrasound yields accurate estimates of volumetric CBF.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 43 条
  • [1] PROFOUND SPATIAL HETEROGENEITY OF CORONARY RESERVE - DISCORDANCE BETWEEN PATTERNS OF RESTING AND MAXIMAL MYOCARDIAL BLOOD-FLOW
    AUSTIN, RE
    ALDEA, GS
    COGGINS, DL
    FLYNN, AE
    HOFFMAN, JIE
    [J]. CIRCULATION RESEARCH, 1990, 67 (02) : 319 - 331
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Burton RG, 1984, MED ELECTRONICS, V15, P68
  • [4] EFFECTS OF INHIBITION OF NITRIC-OXIDE FORMATION ON BASAL VASOMOTION AND ENDOTHELIUM-DEPENDENT RESPONSES OF THE CORONARY-ARTERIES IN AWAKE DOGS
    CHU, A
    CHAMBERS, DE
    LIN, CC
    KUEHL, WD
    PALMER, RMJ
    MONCADA, S
    COBB, FR
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1991, 87 (06) : 1964 - 1968
  • [5] PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN
    COLE, JS
    HARTLEY, CJ
    [J]. CIRCULATION, 1977, 56 (01) : 18 - 25
  • [6] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [7] MEASUREMENT OF CORONARY AND PERIPHERAL ARTERY FLOW BY INTRAVASCULAR ULTRASOUND AND PULSED DOPPLER VELOCIMETRY
    EICHHORN, EJ
    ALVAREZ, LG
    JESSEN, ME
    FASS, SM
    CHAO, RY
    HAAGEN, D
    GRAYBURN, PA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04) : 542 - 545
  • [8] EVANS J L, 1992, Journal of the American College of Cardiology, V19, p140A
  • [9] REGIONAL AND CARDIAC HEMODYNAMIC-EFFECTS OF NG-NITRO-L-ARGININE METHYL-ESTER IN CONSCIOUS, LONG EVANS RATS
    GARDINER, SM
    COMPTON, AM
    KEMP, PA
    BENNETT, T
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1990, 101 (03) : 625 - 631
  • [10] CLASSIFICATION OF MORPHOLOGIC EFFECTS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY ASSESSED BY INTRAVASCULAR ULTRASOUND
    GERBER, TC
    ERBEL, R
    GORGE, G
    GE, J
    RUPPRECHT, HJ
    MEYER, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (20) : 1546 - 1554