MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW BY SIMULTANEOUS INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND - VALIDATION IN AN ANIMAL-MODEL

被引:41
作者
CHOU, TM [1 ]
SUDHIR, K [1 ]
IWANAGA, S [1 ]
CHATTERJEE, K [1 ]
YOCK, PG [1 ]
机构
[1] BAKER MED RES INST, ALFRED & BAKER MED UNIT, MELBOURNE, VIC, AUSTRALIA
关键词
D O I
10.1016/0002-8703(94)90474-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We examined the accuracy and feasibility of using simultaneous intracoronary Doppler and two-dimensional (2D) ultrasound imaging in the measurement of volumetric coronary blood flow (CBF). A femoral artery-to-circumflex coronary artery shunt was created in four dogs with tubing that incorporated an in-line transit-time ultrasound (TTU) flow probe. A 2D ultrasound catheter was introduced over a 0.014-inch Doppler guide wire into the circumflex artery with the guide wire tip positioned 2 cm beyond the imaging catheter tip. Cross-sectional area (CSA) and average peak velocity (APV) were recorded. CBF was determined from the previously validated relation CBF = CSA X 0.5 APV and the adjusted measurement formula CBF = CSA X 0.47 APV. Within the 119 measurements made, TTU CBF varied from 31 to 385 ml/min. An excellent correlation was found between 2D/Doppler-derived and TTU CBF with both constants; measurement agreement was improved and bias minimal with the 0.47 constant (slope = 0.9997; r = 0.99: p < 0.0001; SEE = - 6.7 +/- 8.6). We conclude that simultaneous 2D and Doppler ultrasound yields accurate estimates of volumetric CBF.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 43 条
  • [31] STGOAR FG, 1991, J AM COLL CARDIOL, V18, P952
  • [32] ASSESSMENT OF CORONARY CONDUCTANCE AND RESISTANCE VESSEL REACTIVITY IN RESPONSE TO NITROGLYCERIN, ERGONOVINE AND ADENOSINE - INVIVO STUDIES WITH SIMULTANEOUS INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND
    SUDHIR, K
    MACGREGOR, JS
    BARBANT, SD
    FOSTER, E
    FITZGERALD, PJ
    CHATTERJEE, K
    YOCK, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1261 - 1268
  • [33] MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW WITH A DOPPLER CATHETER - VALIDATION IN AN ANIMAL-MODEL
    SUDHIR, K
    HARGRAVE, VK
    JOHNSON, EL
    ALDEA, G
    MORI, H
    PORTS, TA
    YOCK, PG
    [J]. AMERICAN HEART JOURNAL, 1992, 124 (04) : 870 - 875
  • [34] EFFECT OF SELECTIVE ANGIOTENSIN-II RECEPTOR ANTAGONISM AND ANGIOTENSIN CONVERTING ENZYME-INHIBITION ON THE CORONARY VASCULATURE INVIVO - INTRAVASCULAR 2-DIMENSIONAL AND DOPPLER ULTRASOUND STUDIES
    SUDHIR, K
    MACGREGOR, JS
    GUPTA, M
    BARBANT, SD
    REDBERG, R
    YOCK, PG
    CHATTERJEE, K
    [J]. CIRCULATION, 1993, 87 (03) : 931 - 938
  • [35] SUDHIR K, 1992, Journal of the American College of Cardiology, V19, p140A
  • [36] DIFFERENTIAL CONTRIBUTION OF NITRIC-OXIDE TO REGULATION OF VASCULAR TONE IN CORONARY CONDUCTANCE AND RESISTANCE ARTERIES - INTRAVASCULAR ULTRASOUND STUDIES
    SUDHIR, K
    MACGREGOR, JS
    AMIDON, TM
    GUPTA, M
    YOCK, PG
    CHATTERJEE, K
    [J]. AMERICAN HEART JOURNAL, 1994, 127 (04) : 858 - 865
  • [37] ACCURACY OF 20-MHZ DOPPLER CATHETER CORONARY-ARTERY VELOCIMETRY FOR MEASUREMENT OF CORONARY BLOOD-FLOW VELOCITY
    TADAOKA, S
    KAGIYAMA, M
    HIRAMATSU, O
    OGASAWARA, Y
    TSUJIOKA, K
    WADA, Y
    SAWAYAMA, T
    KAJIYA, F
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (03): : 205 - 213
  • [38] WHITE CW, 1989, BIBL CARDIOL, V44, P155
  • [39] PREDICTION OF THE PHYSIOLOGICAL SIGNIFICANCE OF CORONARY ARTERIAL LESIONS BY QUANTITATIVE LESION GEOMETRY IN PATIENTS WITH LIMITED CORONARY-ARTERY DISEASE
    WILSON, RF
    MARCUS, ML
    WHITE, CW
    [J]. CIRCULATION, 1987, 75 (04) : 723 - 732
  • [40] TRANS-LUMINAL, SUBSELECTIVE MEASUREMENT OF CORONARY-ARTERY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN MAN
    WILSON, RF
    LAUGHLIN, DE
    ACKELL, PH
    CHILIAN, WM
    HOLIDA, MD
    HARTLEY, CJ
    ARMSTRONG, ML
    MARCUS, ML
    WHITE, CW
    [J]. CIRCULATION, 1985, 72 (01) : 82 - 92