MAGNETIC-RESONANCE ANGIOGRAPHY TECHNIQUES

被引:16
作者
PRICE, RR
CREASY, JL
LORENZ, CH
PARTAIN, CL
机构
关键词
MAGNETIC RESONANCE ANGIOGRAPHY; PHASE CONTRAST; TIME OF FLIGHT;
D O I
10.1097/00004424-199212002-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
After a radio frequency pulse, the decay of the magnetic resonance (MR) signal is described by two relaxation processes, T1 and T2. T1 describes the rate at which the magnetization realigns itself along the external magnetic field direction (M(L)), and T2 describes the rate of decay of the magnetization component along the transverse axis (M(T)). Magnetic resonance angiography (MRA) sequences have been developed that encode flow as changes in the apparent T1 or T2 of the moving blood relative to stationary tissues. MRA sequences typically use either time-of-flight (TOF) techniques to encode T1 or phase-contrast techniques to encode T2. TOF techniques encode flow as an apparent T1 shortening through the wash-in of fully relaxed blood from outside the image volume. The shorter TI produces an enhancement of vascular structures relative to stationary tissues. TOF methods may use either sequential two-dimensional, three-dimensional, or multi-slab three-dimensional imaging sequences to produce a three-dimensional MRA data set. Phase-contrast methods use additional magnetic field gradients to encode flow as shifts in the phase of M(T). Both TOF and phase-contrast methods use maximum intensity projection (MIP) images displayed in a cine format to aid in the visualization of three-dimensional vascular structures.
引用
收藏
页码:S27 / S32
页数:6
相关论文
共 9 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[3]   MR VASCULAR IMAGING WITH A FAST GRADIENT REFOCUSING PULSE SEQUENCE AND REFORMATTED IMAGES FROM TRANSAXIAL SECTIONS [J].
GULLBERG, GT ;
WEHRLI, FW ;
SHIMAKAWA, A ;
SIMONS, MA .
RADIOLOGY, 1987, 165 (01) :241-246
[4]  
HAAKE EM, 1989, MAGNET RESON MED, V14, P202
[5]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[6]   GRADIENT MOMENT NULLING THROUGH THE NTH MOMENT - APPLICATION OF BINOMIAL EXPANSION COEFFICIENTS TO GRADIENT AMPLITUDES [J].
KELLER, PJ ;
WEHRLI, FW .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :145-149
[7]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[8]   MR ANGIOGRAPHY BY MULTIPLE THIN SLAB 3D ACQUISITION [J].
PARKER, DL ;
YUAN, C ;
BLATTER, DD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :434-451
[9]   VOLUME MR ANGIOGRAPHY - METHODS TO ACHIEVE VERY SHORT ECHO TIMES [J].
SCHMALBROCK, P ;
YUAN, C ;
CHAKERES, DW ;
KOHLI, J ;
PELC, NJ .
RADIOLOGY, 1990, 175 (03) :861-865