TANDEM REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER UTILIZING PHOTODISSOCIATION

被引:38
作者
BEUSSMAN, DJ [1 ]
VLASAK, PR [1 ]
MCLANE, RD [1 ]
SEETERLIN, MA [1 ]
ENKE, CG [1 ]
机构
[1] MICHIGAN STATE UNIV,DEPT CHEM,E LANSING,MI 48824
关键词
D O I
10.1021/ac00117a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A tandem time-of-flight (TOF) mass spectrometer has been designed to obtain complete MS/MS spectra from compounds eluting from a gas chromatograph, This application requires high spectral generation rate, unit mass resolution for both precursor selection and product spectra, and efficient ion utilization, These objectives are achieved by reflectron TOF mass separation in both stages and laser photoinduced dissociation as the ion fragmentation method, Careful timing of the laser pulse relative to ion extraction allows ions of a single m/z value up to m/z 1000 to be photodissociated while ions with adjacent m/z values are essentially unaffected, The convergent foci of the ion packet and laser pulse results in ion fragmentation efficiencies as high as 79%, An ion gate prevents the nonselected precursor ions from convoluting the product spectra, Product spectra can be generated at the maximum laser repetition rate (currently 200 Hz), To achieve unit mass resolution for all product m/z values simultaneously, a novel reflectron was designed for the second TOF stage.
引用
收藏
页码:3952 / 3957
页数:6
相关论文
共 22 条
  • [1] HIGH-RESOLUTION TIME-OF-FLIGHT MASS SPECTROMETERS .1. EFFECTS OF FIELD DISTORTIONS IN THE VICINITY OF WIRE MESHES
    BERGMANN, T
    MARTIN, TP
    SCHABER, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (03) : 347 - 349
  • [2] MULTIPHOTON DISSOCIATION OF ORGANIC-MOLECULES - STEP BY STEP INVESTIGATION WITH LASER TANDEM MASS-SPECTROMETRY
    BOESL, U
    WEINKAUF, R
    WALTER, K
    WEICKHARDT, C
    SCHLAG, EW
    [J]. BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1990, 94 (11): : 1357 - 1362
  • [3] CONSECUTIVE LASER-INDUCED PHOTODISSOCIATION AS A PROBE OF ION STRUCTURE
    BOWERS, WD
    DELBERT, SS
    MCIVER, RT
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (04) : 969 - 972
  • [4] Absolute values of the electron mobility in hydrogen
    Bradbury, NE
    Nielsen, RA
    [J]. PHYSICAL REVIEW, 1936, 49 (05): : 0388 - 0393
  • [5] CORISH TJ, 1993, J RAPID COMMUN MASS, V7, P1037
  • [6] A COMPACT TIME-OF-FLIGHT MASS-SPECTROMETER FOR THE STRUCTURAL-ANALYSIS OF BIOLOGICAL MOLECULES USING LASER DESORPTION
    CORNISH, T
    COTTER, RJ
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (04) : 242 - 248
  • [7] The rate of formation of negative ions by electron attachment
    Cravath, AM
    [J]. PHYSICAL REVIEW, 1929, 33 (04): : 0605 - 0613
  • [8] GARDNER BD, 1993, 42ND P ASMS C MASS S, P1037
  • [9] AN ELECTRON-IMPACT STORAGE ION-SOURCE FOR TIME-OF-FLIGHT MASS SPECTROMETERS
    GRIX, R
    GRUNER, U
    LI, G
    STROH, H
    WOLLNIK, H
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 93 (03): : 323 - 330
  • [10] DESIGN, CONSTRUCTION, AND EVALUATION OF AN INTEGRATING TRANSIENT RECORDER FOR DATA ACQUISITION IN CAPILLARY GAS-CHROMATOGRAPHY TIME-OF-FLIGHT MASS-SPECTROMETRY
    HOLLAND, JF
    NEWCOMBE, B
    TECKLENBURG, RE
    DAVENPORT, M
    ALLISON, J
    WATSON, JT
    ENKE, CG
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (01) : 69 - 76