DIGITAL ACOUSTICAL ANALYSIS OF NORMAL AND BIMODAL BJORK-SHILEY 60-DEGREES CONVEXO-CONCAVE HEART-VALVES

被引:6
作者
KIEN, GA
JEFFRIES, B
KATZ, HV
HERMAN, BA
CAREY, RF
CHWIRUT, DJ
BUSHAR, HF
机构
[1] INT ACOUST INC,PALATINE,IL
[2] US FDA,CTR DEVICE & RADIOL HLTH,ROCKVILLE,MD 20857
关键词
D O I
10.1016/0002-9149(90)90363-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fracture of the outlet strut of the Björk-Shiley 60 ° convexo-concave (BS60CC) valve has been attributed to a bimodal closing pattern in certain valves in which the closing disk rotates about the inlet strut, causing upward displacement of the outlet strut and its eventual fracture. This article reports the in vivo studies of the normal BS60CC valve and the in vitro studies of the normal and bimodal BS60CC valves, using a digitial acoustical signal processing technique, in which the individual collisions (impact history) of the occluder disk with the components of the valve body are revealed during each closing cycle. In vitro analysis of the closing acoustical signals of normal BS60CC valves showed impact history cluster width (IHCW) means of 2.07 ± 0.85 ms (standard error), not significantly different from those of 1.86 ± 0.58 ms (standard error) observed in 38 clinically normal patients with BS60CC valves (p >0.1). The bimodal valves showed IHCW of 6.14 ± 0.98 ms (standard error), in vitro, which was significantly greater than those observed in the normal in vitro valve group and in the normal patient population (p < 0.0001). © 1990.
引用
收藏
页码:849 / 854
页数:6
相关论文
共 28 条
[11]   OUTLET STRUT FRACTURE OF THE BJORK-SHILEY 60-DEGREES CONVEXO-CONCAVE VALVE - CURRENT INFORMATION AND RECOMMENDATIONS FOR PATIENT-CARE [J].
HIRATZKA, LF ;
KOUCHOUKOS, NT ;
GRUNKEMEIER, GL ;
MILLER, DC ;
SCULLY, HE ;
WECHSLER, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (05) :1130-1137
[12]  
HORSTKOTTE D, 1983, CIRCULATION, V68, P175
[13]  
IBARRA F, 1984, J THORAC CARDIOV SUR, V87, P315
[14]  
JAUMIN P, 1984, J THORAC CARDIOV SUR, V88, P787
[15]   DISK AND STRUT EMBOLIZATION AFTER MINOR STRUT FRACTURE IN A BJORK-SHILEY MITRAL-VALVE PROSTHESIS [J].
KHALIL, Y ;
SETHIA, B ;
QUIN, RO ;
BAIN, WH .
THORAX, 1985, 40 (02) :158-159
[16]  
KUPARI M, 1986, BRIT HEART J, V55, P364
[17]   STRUT FRACTURE AND DISK EMBOLIZATION OF A BJORK-SHILEY MITRAL-VALVE PROSTHESIS - LOCALIZATION OF EMBOLIZED DISK BY COMPUTERIZED AXIAL-TOMOGRAPHY [J].
LARRIEU, AJ ;
PUGLIA, E ;
ALLEN, P .
ANNALS OF THORACIC SURGERY, 1982, 34 (02) :192-195
[18]  
LIFSCHULTZ BD, 1985, J FORENSIC SCI, V39, P1244
[19]  
LINDBLOM D, 1986, J THORAC CARDIOV SUR, V92, P894
[20]  
LINDBLOM D, 1989, J THORAC CARDIOV SUR, V97, P95