SHORT-TERM REPRODUCIBILITY OVER TIME OF RIGHT VENTRICULAR PULSE PRESSURE AS A POTENTIAL HEMODYNAMIC SENSOR FOR VENTRICULAR TACHYARRHYTHMIAS

被引:5
作者
ELLENBOGEN, KA
WOOD, MA
KAPADIA, K
LU, B
VALENTA, H
机构
[1] HUNTER HOLMES MCGUIRE VET ADM MED CTR,RICHMOND,VA
[2] TELECTR PACING SYST,DENVER,CO
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1992年 / 15卷 / 07期
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD); VENTRICULAR TACHYARRHYTHMIA; RIGHT VENTRICULAR PULSE PRESSURE;
D O I
10.1111/j.1540-8159.1992.tb03088.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantable cardioverter defibrillator [ICD] has been shown to effectively terminate episodes of ventricular tachyarrhythmias. Multiple investigators have suggested that the incorporation of hemodynamic sensors may allow ICDs to differentiate between hemodynamically unstable and stable ventricular tachyarrhythmias [VT], as well as differentiate ventricular from supraventricular tachycardias. Right ventricular [RV] pulse pressure has been shown to possess acceptable characteristics as a sensor for incorporation in ICDs. We sought to determine the short-term reproducibility of RV pulse pressure measurements by comparing RV pulse pressure measured during two separate episodes of VT in each of ten study patients. The mean VT cycle length for VT episode 1 was 293 +/- 15 msec, and was 298 +/- 15 msec for VT episode 2 [P = NS]. The decrease in mean arterial pressure was 40 +/- 7 mmHg in episode 1 and 37 +/- 7 mmHg in episode 2 [P = NS]. The decrease in RV pulse pressure during episode 1 was - 13 +/- 2 mmHg, and - 12 +/- 2 during episode 2 [P = NS]. The decrease in RV pulse pressure during episodes of VT at two different times during a single electrophysiology study is highly reproducible, suggesting that RV pulse pressure may be a reliable sensor over time.
引用
收藏
页码:971 / 974
页数:4
相关论文
共 7 条
[1]   A HEMODYNAMICALLY RESPONSIVE ANTITACHYCARDIA SYSTEM - DEVELOPMENT AND BASIS FOR DESIGN IN HUMANS [J].
COHEN, TJ ;
LIEM, LB .
CIRCULATION, 1990, 82 (02) :394-406
[2]   USEFULNESS OF RIGHT VENTRICULAR PULSE PRESSURE AS A POTENTIAL SENSOR FOR HEMODYNAMICALLY UNSTABLE VENTRICULAR-TACHYCARDIA [J].
ELLENBOGEN, KA ;
LU, B ;
KAPADIA, K ;
WOOD, M ;
VALENTA, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (16) :1105-1111
[3]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN DRUG-REFRACTORY VENTRICULAR TACHYARRHYTHMIAS [J].
FOGOROS, RN ;
FIEDLER, SB ;
ELSON, JJ .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (05) :635-641
[4]   MORTALITY IN PATIENTS WITH IMPLANTED AUTOMATIC DEFIBRILLATORS [J].
MIROWSKI, M ;
REID, PR ;
WINKLE, RA ;
MOWER, MM ;
WATKINS, L ;
STINSON, EB ;
GRIFFITH, LSC ;
KALLMAN, CH ;
WEISFELDT, ML .
ANNALS OF INTERNAL MEDICINE, 1983, 98 (05) :585-588
[5]   RIGHT VENTRICULAR PRESSURE DURING VENTRICULAR ARRHYTHMIAS IN HUMANS - POTENTIAL IMPLICATIONS FOR IMPLANTABLE ANTITACHYCARDIA DEVICES [J].
SHARMA, AD ;
BENNETT, TD ;
ERICKSON, M ;
KLEIN, GJ ;
YEE, R ;
GUIRAUDON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (03) :648-655
[6]   A PROSPECTIVE-STUDY OF RIGHT VENTRICULAR PULSE PRESSURE AND DP/DT TO DISCRIMINANT-INDUCED VENTRICULAR-TACHYCARDIA FROM SUPRAVENTRICULAR AND SINUS TACHYCARDIA IN MAN [J].
WOOD, M ;
ELLENBOGEN, KA ;
LU, B ;
VALENTA, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (09) :1148-1157
[7]   COMPARISON OF RIGHT VENTRICULAR IMPEDANCE, PULSE PRESSURE AND MAXIMAL DP/DT FOR DETERMINATION OF HEMODYNAMIC STABILITY OF VENTRICULAR ARRHYTHMIAS ASSOCIATED WITH CORONARY-ARTERY DISEASE [J].
WOOD, MA ;
ELLENBOGEN, KA ;
KAPADIA, K ;
LU, B ;
VALENTA, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (05) :575-582