DEVICES FOR INSULIN ADMINISTRATION

被引:84
作者
SELAM, JL [1 ]
CHARLES, MA [1 ]
机构
[1] UNIV CALIF IRVINE, DEPT MED, DIABET RES PROGRAM, IRVINE, CA 92717 USA
关键词
D O I
10.2337/diacare.13.9.955
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is a significant need for revised, safe, and more effective insulin-delivery methods than subcutaneous injections in the treatment of both type I (insulin-dependent) and type II (non-insulin-dependent) diabetes. The aim of this review is to describe the rationale and methods for better use of injection and infusion devices for intensive insulin therapy and to describe results of animal and human research that will lead to an implantable artificial pancreas. Injection devices, e.g., jet injectors, insulin pens, and access ports, cannot be considered as a major breakthrough in the quest for improved control, although they may improve the patient's comfort. External pumps have benefits over multiple injections and conventional insulin therapy only in specific subgroups of patiens, e.g., those with recurrent severe hypoglycemia, but only when used by experienced personnel. The external artificial pancreas (Biostator) is also to be used by experienced personnel for limited clinical and research applications, e.g., surgery of the diabetic patient. The development of an implantable version of the artificial pancreas is linked to progress in the field of reliable long-duration glucose sensors. Finally, programmable implantable insulin pumps, used as an open-loop delivery system, are the most promising alternative to intensive subcutaneous insulin strategies in the short term, although clear evidence of improved safety and efficacy remains to be documented.
引用
收藏
页码:955 / 979
页数:25
相关论文
共 190 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] ADER M, 1987, DIABETES S1, V36, pA182
  • [3] ALBERTI KGM, 1986, DIABETES OBESITY HYP, V681, P471
  • [4] CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS
    ALBISSER, AM
    LEIBEL, BS
    EWART, TG
    DAVIDOVAC, Z
    BOTZ, CK
    ZINGG, W
    SCHIPPER, H
    GANDER, R
    [J]. DIABETES, 1974, 23 (05) : 397 - 404
  • [5] EFFECT OF INTENSIVE INSULIN THERAPY ON GLYCEMIC THRESHOLDS FOR COUNTERREGULATORY HORMONE-RELEASE
    AMIEL, SA
    SHERWIN, RS
    SIMONSON, DC
    TAMBORLANE, WV
    [J]. DIABETES, 1988, 37 (07) : 901 - 907
  • [6] COMMUNITY DIABETES CARE IN THE 1980S
    ANDERSON, RM
    HESS, GE
    DAVIS, WK
    HISS, RG
    [J]. DIABETES CARE, 1988, 11 (07) : 519 - 526
  • [7] INCIDENCE OF HYPOGLYCEMIC EPISODES IN DIABETIC-PATIENTS UNDER CONTINUOUS SUBCUTANEOUS INSULIN INFUSION AND INTENSIFIED CONVENTIONAL INSULIN-TREATMENT - ASSESSMENT BY MEANS OF SEMIAMBULATORY 24-HOUR CONTINUOUS BLOOD-GLUCOSE MONITORING
    ARIAS, P
    KERNER, W
    ZIER, H
    NAVASCUES, I
    PFEIFFER, EF
    [J]. DIABETES CARE, 1985, 8 (02) : 134 - 140
  • [8] FREQUENCY OF DIABETIC-KETOACIDOSIS AND HYPOGLYCEMIC COMA DURING TREATMENT WITH CONTINUOUS SUBCUTANEOUS INSULIN INFUSION - AUDIT OF MEDICAL-CARE
    BENDING, JJ
    PICKUP, JC
    KEEN, H
    [J]. AMERICAN JOURNAL OF MEDICINE, 1985, 79 (06) : 685 - 691
  • [9] OBSERVATIONS ON C-PEPTIDE AND FREE-INSULIN IN THE BLOOD DURING CONTINUOUS SUBCUTANEOUS INSULIN INFUSION AND CONVENTIONAL INSULIN THERAPY
    BERGENSTAL, RM
    DUPRE, J
    LAWSON, PM
    RIZZA, RA
    RUBENSTEIN, AH
    [J]. DIABETES, 1985, 34 : 31 - 36
  • [10] CLINICAL-EXPERIENCE WITH A NEW DEVICE THAT WILL SIMPLIFY INSULIN INJECTIONS
    BERGER, AS
    SAURBREY, N
    KUHL, C
    VILLUMSEN, J
    [J]. DIABETES CARE, 1985, 8 (01) : 73 - 76