DETERMINATION OF AMMONIA IN LOW CONCENTRATIONS WITH NESSLERS REAGENT BY FLOW INJECTION ANALYSIS

被引:122
作者
KRUG, FJ [1 ]
RUZICKA, J [1 ]
HANSEN, EH [1 ]
机构
[1] TECH UNIV DENMARK,CHEM DEPT A,DK-2800 LYNGBY,DENMARK
关键词
Ammonia determination; Continuous-flow measurement; Flow injection analysis; Nessler's reagent; Turbidimetric determination;
D O I
10.1039/an9790400047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A turbidimetric procedure for the determination of ammonia in low concentrations with the use of Nessler's reagent is described. Both natural waters and soil extracts can be analysed at a rate of up to 120 samples per hour with good precision and accuracy. The effects of reagent composition, flow-rate, temperature and protective colloids in the flow injection system are discussed in detail.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 27 条