ESTIMATION OF EXTRAVASCULAR LUNG WATER IN HUMANS WITH USE OF (H2O)-H-2 - EFFECT OF BLOOD-FLOW AND CENTRAL BLOOD-VOLUME

被引:18
作者
WALLIN, CJB [1 ]
LEKSELL, LG [1 ]
机构
[1] KAROLINSKA INST,DEPT ANESTHESIA & INTENS CARE,S-10401 STOCKHOLM,SWEDEN
关键词
INDICATOR DILUTION; DEUTERIUM OXIDE; ANESTHESIA; ABDOMINAL SURGERY; MECHANICAL VENTILATION; POSITIVE END-EXPIRATORY PRESSURE;
D O I
10.1152/jappl.1994.76.5.1868
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In the present human study we evaluated a newly developed double-indicator-dilution densitometric system for the estimation of cardiac output (Q), central blood volume (CBV), and extravascular lung water (EVLW) by using indocyanine green and heavy water ((H2O)-H-2) as indicators. Eighteen cardiopulmonary healthy patients scheduled for abdominal surgery were studied. A routine anesthesia procedure was used [thiopental (3-5 mg/kg), N2O (inspired fraction of O-2 = 0.4), and isoflurane (end tidal 0.5-1.5%)]. Q, CBV, and EVLW were measured at seven defined data collection points: awake, anesthetized spontaneously breathing, apneic, mechanically ventilated with and without positive end-expiratory pressure, postoperatively anesthetized, and postoperatively awake. During the whole study EVLW (3.8 +/- 0.9 ml/kg) was stable in the presence of large fluctuations in Q (2.5-10.1 l/min) and CBV (0.8-2.4 l). We concluded that the method is versatile and of low invasiveness, allowing reliable on-line Q and EVLW data for repeated measurements in the clinical setting.
引用
收藏
页码:1868 / 1875
页数:8
相关论文
共 35 条
[21]  
LILIENFIELD LS, 1954, J CLIN INVEST, V34, P1
[22]   LIMITATIONS OF THERMODILUTION EJECTION FRACTION - DEGRADATION OF FREQUENCY-RESPONSE BY CATHETER MOUNTING OF FAST-RESPONSE THERMISTORS [J].
MARUSCHAK, GF ;
SCHAUBLE, JF .
CRITICAL CARE MEDICINE, 1985, 13 (08) :679-682
[23]   MEASUREMENT OF PULMONARY EDEMA IN VALVULAR HEART DISEASE [J].
MCCREDIE, M .
CIRCULATION, 1967, 36 (03) :381-&
[24]   MEASUREMENT OF EXTRA-VASCULAR LUNG WATER IN DOGS USING THE THERMAL-GREEN DYE INDICATOR DILUTION METHOD [J].
MIHM, FG ;
FEELEY, TW ;
ROSENTHAL, MH ;
LEWIS, F .
ANESTHESIOLOGY, 1982, 57 (02) :116-122
[25]   IMPROVED OUTCOME BASED ON FLUID MANAGEMENT IN CRITICALLY ILL PATIENTS REQUIRING PULMONARY-ARTERY CATHETERIZATION [J].
MITCHELL, JP ;
SCHULLER, D ;
CALANDRINO, FS ;
SCHUSTER, DP .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (05) :990-998
[26]  
NEIDHART P, 1986, ANAESTHESIST, V35, P559
[27]  
NEIDHART PP, 1990, PRACTICAL APPLICATIO, P109
[28]  
NORTON HN, 1969, HDB TRANSDUCERS ELEC, P581
[29]  
RINALDO JE, 1986, AM REV RESPIR DIS, V133, P1006
[30]   EVALUATION OF HEAVY-WATER FOR INDICATOR DILUTION CARDIAC-OUTPUT MEASUREMENT [J].
SCHREINER, MS ;
LEKSELL, LG ;
NEUFELD, GR .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (04) :236-242