共 31 条
COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL ECHOCARDIOGRAPHY WITH CINEVENTRICULOGRAPHY FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN PATIENTS
被引:100
作者:
SAPIN, PM
[1
]
SCHRODER, KM
[1
]
GOPAL, AS
[1
]
SMITH, MD
[1
]
DEMARIA, AN
[1
]
KING, DL
[1
]
机构:
[1] COLUMBIA UNIV,COLL PHYS & SURG,NEW YORK,NY
关键词:
D O I:
10.1016/0735-1097(94)90869-9
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Objectives. We compared two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. Background. Three-dimensional echocardiography has been shown to be highly accurate and superior to two-dimensional echocardiography in measuring left ventricular volume in vitro. However, there has been little comparison of the two methods in patients. Methods. Two- and three-dimensional echocardiography were performed in 35 patients (mean age 48 years) 1 to 3 h before left ventricular cineventriculography. Three-dimensional echocardiography used an acoustic spatial locator to register image position. Volume was computed using a polyhedral surface reconstruction algorithm based on multiple nonparallel, unevenly spaced short-axis cross sections. Two-dimensional echocardiography used the apical biplane summation of disks method. Single plane cineventriculographic volumes were calculated using the summation of disks algorithm. The methods were compared by linear regression and a limits of agreement analysis. For the latter, systematic error was assessed by the mean of the differences (cineventriculography minus echocardiography), and the limits of agreement were defined as +/-2 SD from the mean difference. Results. Three dimensional echocardiographic volumes demonstrated excellent correlation (end-diastole r = 0.97; end-systole r = 0.98) with cineventriculography. Standard errors of the estimate were approximately half those of two-dimensional echocardiography (end-diastole +/-11.0 ml vs. +/-21.5 ml; end-systole +/-10.2 ml vs. +/-17.0 ml). By limits of agreement analysis the end-diastolic mean differences for two- and three-dimensional echocardiography were 21.1 and 12.9 ml, respectively. The limits of agreement (+/-2 SD) were +/-54.0 and +/-24.8 ml, respectively. For end-systole, comparable improvement was obtained by three-dimensional echocardiography. Results for ejection fraction by the two methods were similar. Conclusions. Three-dimensional echocardiography correlates highly with cineventriculography for estimation of ventricular volumes in patients and has approximately half the variability of two-dimensional echocardiography for these measurements. On the basis of this study, three-dimensional echocardiography is the preferred echocardiographic technique for measurement of ventricular volume. Three-dimensional echocardiography is equivalent to two-dimensional echocardiography for measuring ejection fraction.
引用
收藏
页码:1054 / 1063
页数:10
相关论文