EFFECT OF RADIO-FREQUENCY INHOMOGENEITY CORRECTION ON THE REPRODUCIBILITY OF INTRACRANIAL VOLUMES USING MR IMAGE DATA

被引:59
作者
NARAYANA, PA
BORTHAKUR, A
机构
[1] The Department of Radiology, University of Texas Medical School at Houston, Houston, Texas
关键词
BRAIN; MAGNETIC RESONANCE IMAGING; RF INHOMOGENEITY; SEGMENTATION;
D O I
10.1002/mrm.1910330312
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The volumes of total brain, white matter, gray matter, and cerebrospinal fluid in normal volunteers were determined using a supervised nonparametric feature map segmentation of dual-contrast MR images after correcting for the radio frequency (RF) inhomogeneity. Reproducibility of the segmentation was evaluated in terms of inter-observer and scan-to-scan variations. A comparison with the published results indicates that the scan-to-scan and inter-observer variabilities in the determination of tissue volumes are substantially reduced following the RF inhomogeneity correction.
引用
收藏
页码:396 / 400
页数:5
相关论文
共 17 条
[1]   PARTIAL VOLUME TISSUE CLASSIFICATION OF MULTICHANNEL MAGNETIC-RESONANCE IMAGES - A MIXEL MODEL [J].
CHOI, HS ;
HAYNOR, DR ;
KIM, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :395-407
[2]   MRI - STABILITY OF 3 SUPERVISED SEGMENTATION TECHNIQUES [J].
CLARKE, LP ;
VELTHUIZEN, RP ;
PHUPHANICH, S ;
SCHELLENBERG, JD ;
ARRINGTON, JA ;
SILBIGER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (01) :95-106
[3]   3D RECONSTRUCTION OF THE BRAIN FROM MAGNETIC-RESONANCE IMAGES USING A CONNECTIVITY ALGORITHM [J].
CLINE, HE ;
DUMOULIN, CL ;
HART, HR ;
LORENSEN, WE ;
LUDKE, S .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :345-352
[4]   3D SURFACE RENDERED MR IMAGES OF THE BRAIN AND ITS VASCULATURE [J].
CLINE, HE ;
LORENSEN, WE ;
SOUZA, SP ;
JOLESZ, FA ;
KIKINIS, R ;
GERIG, G ;
KENNEDY, TE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :344-351
[5]   3-DIMENSIONAL SEGMENTATION OF MR IMAGES OF THE HEAD USING PROBABILITY AND CONNECTIVITY [J].
CLINE, HE ;
LORENSEN, WE ;
KIKINIS, R ;
JOLESZ, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :1037-1045
[6]  
Duda R. O., 1973, PATTERN CLASSIFICATI, V3
[7]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[8]  
HARRIS GJ, 1994, AM J NEURORADIOL, V15, P225
[9]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[10]   REPRODUCTIBILITY OF NONPARAMETRIC FEATURE MAP SEGMENTATION FOR DETERMINATION OF NORMAL HUMAN INTRACRANIAL VOLUMES WITH MR-IMAGING DATA [J].
JACKSON, EF ;
NARAYANA, PA ;
FALCONER, JC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :692-700