THE ROLE OF ETHYLENE-OXIDE ALLERGY IN STERILE SHUNT MALFUNCTIONS

被引:34
作者
PITTMAN, T
WILIAMS, D
RATHORE, M
KNUTSEN, AP
MUELLER, KR
机构
[1] ST LOUIS UNIV,DIV NEUROL SURG,ST LOUIS,MO 63103
[2] UNIV FLORIDA,DEPT PAEDIAT,JACKSONVILLE,FL
[3] ST LOUIS UNIV,DEPT IMMUNOL & ALLERGY,ST LOUIS,MO 63103
[4] UNIV FLORIDA,DIV NEUROL SCI,JACKSONVILLE,FL
关键词
VP SHUNT; ETHYLENE OXIDE; STERILE SHUNT MALFUNCTION;
D O I
10.3109/02688699409002391
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Failure of an intact ventriculoperitoneal shunt, in the absence of an overt infection, is often due to its occlusion by cellular debris and/or an abdominal pseudocyst. This failure is thought to be caused by an infection by an organism which is difficult to culture or by some poorly defined allergic response to the shunt materials. Little attention has been directed to the treatment that the shunts receive prior to implantation: specifically, their exposure to ethylene oxide as a means of sterilization. We have found ethylene oxide metabolites in the spinal fluid of children with shunt malfunction months after their systems were implanted. Many of these patients had coincident CSF eosinophilia. In addition, two of the children had detectable serum IgE antibody directed against an albumin-ethylene oxide conjugated protein. Both of these children had several shunt malfunctions within a short period, yet neither child could be shown to have a shunt infection despite multiple cultures. We therefore suggest that in some patients proteins altered by ethylene oxide incite an IgE mediated response which may lead to shunt malfunction.
引用
收藏
页码:41 / 45
页数:5
相关论文
共 23 条
[1]  
ANDERSEN SR, 1971, J LAB CLIN MED, V77, P346
[2]   A RAPID, SENSITIVE METHOD FOR DETECTION OF ALKALINE-PHOSPHATASE CONJUGATED ANTI-ANTIBODY ON WESTERN BLOTS [J].
BLAKE, MS ;
JOHNSTON, KH ;
RUSSELLJONES, GJ ;
GOTSCHLICH, EC .
ANALYTICAL BIOCHEMISTRY, 1984, 136 (01) :175-179
[3]   STERILE SHUNT MALFUNCTION - A SCANNING ELECTRON-MICROSCOPIC PERSPECTIVE [J].
GOWER, DJ ;
LEWIS, JC ;
KELLY, DL .
JOURNAL OF NEUROSURGERY, 1984, 61 (06) :1079-1084
[4]   CHARACTERIZATION OF AN ANTIGEN IN ACUTE ANAPHYLACTIC DIALYSIS REACTIONS - ETHYLENE-OXIDE ALTERED HUMAN-SERUM ALBUMIN [J].
GRAMMER, LC ;
SHAUGHNESSY, MA ;
PATERSON, BF ;
PATTERSON, R .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1985, 76 (05) :670-675
[5]   IGE AGAINST ETHYLENE OXIDE-ALTERED HUMAN-SERUM ALBUMIN (ETO-HSA) AS AN ETIOLOGIC AGENT IN ALLERGIC REACTIONS OF HEMODIALYSIS-PATIENTS [J].
GRAMMER, LC ;
PATTERSON, R .
ARTIFICIAL ORGANS, 1987, 11 (02) :97-99
[6]   IGE AGAINST ETHYLENE OXIDE ALTERED HUMAN-SERUM ALBUMIN IN PATIENTS WITH ANAPHYLACTIC REACTIONS TO DIALYSIS [J].
GRAMMER, LC ;
PATERSON, BF ;
ROXE, D ;
DAUGIRDAS, JT ;
ING, TS ;
IVANOVICH, PT ;
BROWN, CB ;
NICHOLLS, AJ ;
PATTERSON, R .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1985, 76 (03) :511-514
[7]   INTRAARTICULAR REACTION ASSOCIATED WITH THE USE OF FREEZE-DRIED, ETHYLENE OXIDE-STERILIZED BONE-PATELLA TENDON-BONE ALLOGRAFTS IN THE RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT [J].
JACKSON, DW ;
WINDLER, GE ;
SIMON, TM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1990, 18 (01) :1-11
[8]  
KENNEDY CR, 1988, DEV MED CHILD NEUROL, V30, P386
[9]   EOSINOPHILIA OF THE CEREBROSPINAL FLUID OF NONINFECTIOUS ORIGIN - REPORT OF 2 CASES [J].
KESSLER, LA ;
CHEEK, WR .
NEUROLOGY, 1959, 9 (05) :371-374
[10]  
KOSSOUSKY N, 1983, SURG FORUM, P527