NORMALIZED AVERAGE GLANDULAR DOSE IN MOLYBDENUM TARGET RHODIUM FILTER AND RHODIUM TARGET RHODIUM FILTER MAMMOGRAPHY

被引:185
作者
WU, XZ
GINGOLD, EL
BARNES, GT
TUCKER, DM
机构
[1] Department of Radiology, Univ. Alabama Hospitals and Clinics, University of Alabama at Birmingham, Birmingham, AL 35233-1924
关键词
BREAST RADIOGRAPHY; RADIATION DOSE; TECHNOLOGY; DOSIMETRY; FILTERS; RADIOGRAPHIC; RADIOGRAPHY; COMPARATIVE STUDIES;
D O I
10.1148/radiology.193.1.8090926
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the normalized glandular dose ((D) over bar(gN)) for molybdenum target-rhodium filter (Mo-Rh) and rhodium target-rhodium filter (Rh-Rh) mammography and compare the average glandular doses ((D) over bar(g)) that resulted with a conventional molybdenum target-molybdenum filter (Mo-Mo) source assembly. MATERIALS AND METHODS: X-ray spectra models for Mo-Rh and Rh-Rh were developed and used to calculate (D) over bar(gN) values for these target-filter combinations as a function of x-ray tube potential, half-value layer, and breast thickness for three breast compositions. For the average glandular dose comparisons, 50/50 phantoms were imaged for the three target-filter source assemblies at three tube potentials. RESULTS: For the same parameters, (D) over bar(gN) values for Mo-Rh and Rh-Rh were higher than for Mo-Mo. At the same voltage, the exposures required to image breast phantoms are substantially lower, and as a result, (D) over bar(gs) are also less with Mo-Rh and Rh-Rh than with Mo-Mo. CONCLUSION: (D) over bar(gN) values presented permit practical evaluations of average glandular doses for Mo-Rh and Rh-Rh mammography. At a given potential, dose savings are realized with Mo-Rh and Rh-Rh source assemblies.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 11 条
[1]  
DYSON NA, 1973, XRAYS ATOMIC NUCLEAR
[2]  
HOLT JG, 1975, MED PHYS, V2, P175
[3]   MOLYBDENUM TARGET X-RAY-SPECTRA - A SEMIEMPIRICAL MODEL [J].
TUCKER, DM ;
BARNES, GT ;
WU, XZ .
MEDICAL PHYSICS, 1991, 18 (03) :402-407
[4]   SEMIEMPIRICAL MODEL FOR GENERATING TUNGSTEN TARGET X-RAY-SPECTRA [J].
TUCKER, DM ;
BARNES, GT ;
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1991, 18 (02) :211-218
[5]  
WAGNER LK, 1990, MED PHYS, V17, P989, DOI 10.1118/1.596444
[6]   SPECTRAL DEPENDENCE OF GLANDULAR TISSUE DOSE IN SCREEN-FILM MAMMOGRAPHY [J].
WU, XZ ;
BARNES, GT ;
TUCKER, DM .
RADIOLOGY, 1991, 179 (01) :143-148
[7]  
1993, CFR 900, V21
[8]  
1986, NCRP85 NAT COUNC RAD
[9]  
1983, CANCER J CLIN, V33, P255
[10]  
1992, ACR MAMMOGRAPHY ACCR