ANALYTICAL CALCULATIONS AND MONTE-CARLO SIMULATIONS OF LASER DOPPLER FLOWMETRY USING A CUBIC LATTICE MODEL

被引:7
作者
KOELINK, MH
DEMUL, FFM
GREVE, J
GRAAFF, R
DASSEL, ACM
AARNOUDSE, JG
机构
[1] UNIV GRONINGEN HOSP,DEPT OBSTET & GYNECOL,9713 EZ GRONINGEN,NETHERLANDS
[2] UNIV GRONINGEN HOSP,CTR BIOMED TECHNOL,9713 EZ GRONINGEN,NETHERLANDS
来源
APPLIED OPTICS | 1992年 / 31卷 / 16期
关键词
D O I
10.1364/AO.31.003061
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In addition to the static cubic lattice model for photon migration in turbid biological media by Bonner et al. [J. Opt. Soc. Am. A 4, 423-432 (1987)], a dynamic method is presented to calculate the average absolute Doppler shift as a function of the distance between the point of injection of photons into the medium and the point of detection. At every lattice point a moving particle is assumed with a constant velocity in random directions. The velocity direction fluctuates randomly in time. When a photon is scattered at a lattice point it has a finite probability to be Doppler shifted, since in reality not every scattering event occurs with a moving particle. Calculated average absolute Doppler shifts are verified with Monte Carlo simulations. We verified the applicability of the derived formulas for continuous isotropic and continuous anisotropic media. Good agreement is found between the calculated and simulated average absolute Doppler shifts. Small differences between calculated and simulated average absolute Doppler shifts can be explained by the assumptions made in the theory. Furthermore the calculations of the average absolute Doppler shift confirm the theory of Bonner et al. that the first moment [omega] of a spectrum S(omega) measured with a blood perfusion meter is linearly proportional to the average number m of scattering events with a moving particle in case of m < 1 and linearly proportional to the square root of m in the case of m > 1. It is confirmed that the average absolute Doppler shift depends on the average number of scattering events at the position of the detection. This effect is, apart from the size and position of the probe volume, essential for the interpretation of the signal measured with a laser Doppler perfusion meter.
引用
收藏
页码:3061 / 3067
页数:7
相关论文
共 6 条
[1]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[2]   MODEL FOR PHOTON MIGRATION IN TURBID BIOLOGICAL MEDIA [J].
BONNER, RF ;
NOSSAL, R ;
HAVLIN, S ;
WEISS, GH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (03) :423-432
[3]   LASER DOPPLER FLOWMETRY - MEASUREMENTS IN A LAYERED PERFUSION MODEL AND MONTE-CARLO SIMULATIONS OF MEASUREMENTS [J].
JENTINK, HW ;
DEMUL, FFM ;
GRAAFF, R ;
SUICHIES, HE ;
AARNOUDSE, JG ;
GREVE, J .
APPLIED OPTICS, 1991, 30 (18) :2592-2597
[4]   MONTE-CARLO SIMULATIONS OF LASER DOPPLER BLOOD-FLOW MEASUREMENTS IN TISSUE [J].
JENTINK, HW ;
DEMUL, FFM ;
HERMSEN, RGAM ;
GRAAFF, R ;
GREVE, J .
APPLIED OPTICS, 1990, 29 (16) :2371-2381
[5]  
JENTINK HW, 1989, SEP M LAS AN ADV APP
[6]   INFLUENCE OF PATH-LENGTH ON REMOTE OPTICAL SENSING OF PROPERTIES OF BIOLOGICAL TISSUE [J].
NOSSAL, R ;
BONNER, RF ;
WEISS, GH .
APPLIED OPTICS, 1989, 28 (12) :2238-2244