LASER DOPPLER FLOWMETRY - MEASUREMENTS IN A LAYERED PERFUSION MODEL AND MONTE-CARLO SIMULATIONS OF MEASUREMENTS

被引:11
作者
JENTINK, HW [1 ]
DEMUL, FFM [1 ]
GRAAFF, R [1 ]
SUICHIES, HE [1 ]
AARNOUDSE, JG [1 ]
GREVE, J [1 ]
机构
[1] UNIV GRONINGEN HOSP,DEPT OBSTET & GYNECOL,9713 EZ GRONINGEN,NETHERLANDS
来源
APPLIED OPTICS | 1991年 / 30卷 / 18期
关键词
D O I
10.1364/AO.30.002592
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fluid flow in a flow model was measured with a laser Doppler flowmeter normally used for tissue perfusion measurements. The flow parameter is deduced from the first moment of the spectral power density of intensity fluctuations at a detector viewing the model, which is illuminated by a laser. The model consisted of layers, filled with liquid, containing scattering particles, at different distances to the optics of the flowmeter. To each of the layers a flow can be applied. The configuration of the optical components could be varied, which resulted in an adjustable relative sensitivity for the flow in the different layers. Here, the feasibility of depth-dependent flowmetry with the laser Doppler flowmeter is shown experimentally. The measurements in the flow model were simulated with Monte Carlo calculations. The results indicate that these calculations may be of help to interpret experimentally obtained flow results.
引用
收藏
页码:2592 / 2597
页数:6
相关论文
共 9 条
[1]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[2]   ASPECTS OF LASER-LIGHT SCATTERING FROM SKIN TISSUE WITH APPLICATION TO LASER DOPPLER BLOOD-FLOW MEASUREMENT [J].
GUSH, RJ ;
KING, TA ;
JAYSON, MIV .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (12) :1463-1476
[3]   PARTITIONAL MEASUREMENT OF CAPILLARY AND ARTERIOVENOUS ANASTOMOTIC BLOOD-FLOW IN THE HUMAN FINGER BY LASER-DOPPLER-FLOWMETER [J].
HIRATA, K ;
NAGASAKA, T ;
NODA, Y .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1988, 57 (05) :616-621
[4]  
Ishimaru A., 1978, WAVE PROPAGATION SCA, V1
[5]   MONTE-CARLO SIMULATIONS OF LASER DOPPLER BLOOD-FLOW MEASUREMENTS IN TISSUE [J].
JENTINK, HW ;
DEMUL, FFM ;
HERMSEN, RGAM ;
GRAAFF, R ;
GREVE, J .
APPLIED OPTICS, 1990, 29 (16) :2371-2381
[6]   A COMPACT DIFFERENTIAL LASER DOPPLER-VELOCIMETER USING A SEMICONDUCTOR-LASER [J].
JENTINK, HW ;
VANBEURDEN, JAJ ;
HELSDINGEN, MA ;
DEMUL, FFM ;
SUICHIES, HE ;
AARNOUDSE, JG ;
GREVE, J .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (10) :1281-1283
[7]  
JENTINK HW, 1987, 2ND P INT C LAS AN S, P225
[8]   INFLUENCE OF PATH-LENGTH ON REMOTE OPTICAL SENSING OF PROPERTIES OF BIOLOGICAL TISSUE [J].
NOSSAL, R ;
BONNER, RF ;
WEISS, GH .
APPLIED OPTICS, 1989, 28 (12) :2238-2244
[9]   DEPTH DISCRIMINATION IN LASER DOPPLER SKIN BLOOD-FLOW MEASUREMENT USING DIFFERENT LASERS [J].
OBEID, AN ;
BOGGETT, DM ;
BARNETT, NJ ;
DOUGHERTY, G ;
ROLFE, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :415-419