RELIABLE AND VERY SENSITIVE FLOW-CYTOMETRIC METHOD FOR COUNTING LOW LEUKOCYTE NUMBERS IN PLATELET CONCENTRATES

被引:12
作者
DENEYS, V [1 ]
MAZZON, AM [1 ]
ROBERT, A [1 ]
DUVILLIER, H [1 ]
DEBRUYERE, M [1 ]
机构
[1] UNIV CATHOLIQUE LOUVAIN,INST STAT,B-1200 BRUSSELS,BELGIUM
关键词
D O I
10.1111/j.1423-0410.1994.tb01654.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reduction of leucocytes in blood components, achieved by filtration, may reduce the risk of HLA alloimmunization, virus transmission, and febrile reactions. Nevertheless, white blood cell (WBC) concentrations obtained in this way can be too low to be accurately counted with automated and manual techniques. We describe here a rapid, reliable, and very sensitive method for counting low leucocyte numbers using flow cytometry. WBC nuclei are labelled by propidium iodide. A known amount of fluorescein- and phycoerythrin-conjugated beads (Standard Brite, Coulter) is added as an indicator of the examined volume. The time required for analyzing one tube is approximately 5 min. This method was first validated by comparing WBC counts (120-2,570/mu l) assessed on a haemocytometer (Burker) and by flow cytometry. The second step was to determine the sensitivity of the method: we diluted normal platelet concentrates with phosphate-buffered saline. The comparison of expected with observed values showed a very good correlation up to a concentration of 1 WBC/mu l. This technique is an accurate method that can be applied in blood bank quality controls and in clinical studies.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 12 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   A FLOW CYTOMETRIC TECHNIQUE TO ACCURATELY MEASURE POST-FILTRATION WHITE BLOOD-CELL COUNTS [J].
BODENSTEINER, DC .
TRANSFUSION, 1989, 29 (07) :651-653
[3]   SAMPLING ERRORS AND THE PRECISION ASSOCIATED WITH COUNTING VERY LOW NUMBERS OF WHITE CELLS IN BLOOD COMPONENTS [J].
DUMONT, LJ .
TRANSFUSION, 1991, 31 (05) :428-432
[4]   FLOW-CYTOMETRIC METHOD FOR COUNTING VERY LOW NUMBERS OF LEUKOCYTES IN PLATELET PRODUCTS [J].
DZIK, WH ;
RAGOSTA, A ;
CUSACK, WF .
VOX SANGUINIS, 1990, 59 (03) :153-159
[5]  
FISCHER M, 1985, VOX SANG, V49, P331
[6]  
JULLIEN AM, 1993, NOUV REV FR HEMATOL, V35, P211
[7]   VALIDATION OF A SIMPLE METHOD TO COUNT VERY LOW WHITE CELL CONCENTRATIONS IN FILTERED RED-CELLS OR PLATELETS [J].
MASSE, M ;
NAEGELEN, C ;
PELLEGRINI, N ;
SEGIER, JM ;
MARPAUX, N ;
BEAUJEAN, F .
TRANSFUSION, 1992, 32 (06) :565-571
[8]   A MULTICENTER STUDY ON THE EFFICIENCY OF WHITE CELL REDUCTION BY FILTRATION OF RED-CELLS [J].
MASSE, M ;
ANDREU, G ;
ANGUE, M ;
BABAULT, C ;
BEAUJEAN, F ;
BIDET, ML ;
BOUDART, D ;
CALOT, JP ;
COTTE, C ;
FOLLEA, G ;
GEROTA, J ;
HAU, F ;
HUREL, C ;
LEGRAND, E ;
MARCHESSEAU, B ;
NASR, O ;
ROBERT, F ;
ROYER, D ;
SCHOONEMAN, F ;
TARDIVEL, R ;
VIDAL, M .
TRANSFUSION, 1991, 31 (09) :792-797
[9]   LEUKOCYTE-DEPLETED BLOOD - A COMPARISON OF FILTRATION TECHNIQUES [J].
MIJOVIC, V ;
BROZOVIC, B ;
HUGHES, ASB ;
DAVIES, TD .
TRANSFUSION, 1983, 23 (01) :30-32
[10]   WHITE CELL-REDUCED RED-CELLS PREPARED BY FILTRATION - A CRITICAL-EVALUATION OF CURRENT FILTERS AND METHODS FOR COUNTING RESIDUAL WHITE CELLS [J].
REBULLA, P ;
PORRETTI, L ;
BERTOLINI, F ;
MARANGONI, F ;
PRATI, D ;
SMACCHIA, C ;
PAPPALETTERA, M ;
PARRAVICINI, A ;
SIRCHIA, G .
TRANSFUSION, 1993, 33 (02) :128-133