A P-THETA TECHNIQUE FOR TREATMENT VERIFICATION IN RADIOTHERAPY AND ITS CLINICAL-APPLICATIONS

被引:17
作者
DING, GX
SHALEV, S
GLUCHEV, G
机构
[1] Department of Medical Physics, Manitoba Cancer Treatment and Research Foundation, Winnipeg, R3E 0V9
关键词
IMAGE REGISTRATION; P-THETA TECHNIQUE; RADIOTHERAPY TREATMENT VERIFICATION; ONLINE PORTAL IMAGING;
D O I
10.1118/1.596967
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new technique based on a rho-theta coordinate system for determining differences position between portal and simulator images is presented. Unlike the conventional point matching method, which requires the fiducial points to be labeled in pairs before the registration, the rho-theta technique avoids this manual procedure. It accomplishes the treatment verification in two major steps; image alignment and field displacement analysis. For the same number of fiducial points in the simulator and portal images, it first finds the corresponding paired points if the points are not distributed symmetrically about their centroid. This is followed by alignment of these paired points using the least squares matching method to find the optimal two-dimensional rigid body transformation parameters (shift, rotation, and scaling factor). The transformation parameters are then used to transform the portal field edge into the simulator image, so that the portal field can be compared with the prescribed field on the simulator image. A number of parameters were explored to describe the field displacement errors, including treatment field size, under/over irradiated size, the shift in center of gravity of the field, the field edge shift, and rotation of the field. The rho-theta technique as implemented is both fast and accurate. Experiments on the registration of radiological phantom portal images acquired with an on-line portal imaging system mounted on a linear accelerator indicate an accuracy on the order of 1 mm in detecting the shift of the field's center of gravity and approximately 1-degrees in detecting the field rotation. The results of a clinical trial are also presented. The technique appears well suited as an integral part of an automated on-line portal imaging treatment verification system.
引用
收藏
页码:1135 / 1143
页数:9
相关论文
共 10 条
[1]  
BAILY NA, 1980, INT J RADIAT ONCOL, V6, P935, DOI 10.1016/0360-3016(80)90341-7
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]  
CHU T, 1989, MED PHYS, V16, P475
[4]  
Golub G.H., 1983, MATRIX COMPUTATIONS
[5]   USE OF DIGITAL FLUOROSCOPY AS AN ONLINE VERIFICATION DEVICE IN RADIATION-THERAPY [J].
LEONG, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (09) :985-992
[6]   THE ENHANCEMENT OF RADIOTHERAPY VERIFICATION IMAGES BY AN AUTOMATED EDGE-DETECTION TECHNIQUE [J].
LESZCZYNSKI, KW ;
SHALEV, S ;
COSBY, NS .
MEDICAL PHYSICS, 1992, 19 (03) :611-621
[7]   A LIQUID IONIZATION DETECTOR FOR DIGITAL RADIOGRAPHY OF THERAPEUTIC MEGAVOLTAGE PHOTON BEAMS [J].
MEERTENS, H ;
VANHERK, M ;
WEEDA, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :313-321
[8]   A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES [J].
MEERTENS, H ;
BIJHOLD, J ;
STRACKEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :299-323
[9]  
SCHONEMANN PH, 1970, PSYCHOMETRIKA, V35, P247
[10]   VIDEO TECHNIQUES FOR ONLINE PORTAL IMAGING [J].
SHALEV, S ;
LEE, T ;
LESZCZYNSKI, K ;
COSBY, S ;
CHU, T .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (03) :217-226