DEVELOPMENT OF A NEURAL-NETWORK SCREENING AID FOR DIAGNOSING LOWER-LIMB PERIPHERAL VASCULAR-DISEASE FROM PHOTOELECTRIC PLETHYSMOGRAPHY PULSE WAVE-FORMS

被引:52
作者
ALLEN, J
MURRAY, A
机构
[1] Dept. of Regional Med. Phys., Feeman Hospital, Newcastle upon Tyne
关键词
D O I
10.1088/0967-3334/14/1/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An artificial neural network (ANN) was trained to classify photoelectric plethysmographic (PPG) pulse waveforms for the diagnosis of lower limb peripheral vascular disease (PVD). PPG pulses from the lower limbs, and pre- and post-exercise Doppler ultrasound ankle to brachial systolic blood pressure ratio measurements were obtained from patients referred to a vascular investigation laboratory. A single PPG pulse from the big toe of each leg was processed and normalized, and used as input data to the ANN. The ANN outputs represented the diagnostic classifications (normal, significant PVD and major PVD) and the ANN was trained with the ankle to brachial pressure indices (ABPI). The ANN structure consisted of an input layer (50 neuron units from the PPG pulse input), a single hidden layer (15 neurons) and an output layer (3 neurons for the PVD diagnoses). The back-propagation learning algorithm was used to train the ANN for 500 epochs with a PPG training set of pulses from 100 legs. Test data for network assessment comprised pulses from a further 50 legs (20 normal and 30 PVD, Of Which 15 were categorized as having major disease). A network sensitivity of 93% and specificity of 85% was achieved with respect to the Doppler ARPI standard, giving a diagnostic accuracy of 90%. The results of this study indicate that a neural network can be trained to distinguish between PPG pulses from normal and diseased lower limb arteries. The simplicity Of PPG measurement and neural network classification holds promise for the screening of lower limb arterial PVD.
引用
收藏
页码:13 / 22
页数:10
相关论文
共 11 条
[1]  
ABURAHMA AF, 1988, CURRENT NONINVASIVE, P185
[2]  
BAKER JD, 1991, VASCULAR SURGERY COM, P168
[3]  
BARNES RW, 1991, CIRCULATION, V83, P20
[4]   VARIABILITY OF ANKLE AND BRACHIAL SYSTOLIC PRESSURES IN THE MEASUREMENT OF ATHEROSCLEROTIC PERIPHERAL ARTERIAL-DISEASE [J].
FOWKES, FGR ;
HOUSLEY, E ;
MACINTYRE, CCA ;
PRESCOTT, RJ ;
RUCKLEY, CV .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1988, 42 (02) :128-133
[5]  
HERTZER NR, 1991, CIRCULATION, V83, P12
[6]   REPEATABILITY OF PERIPHERAL PULSE MEASUREMENTS ON EARS, FINGERS AND TOES USING PHOTOELECTRIC PLETHYSMOGRAPHY [J].
JAGO, JR ;
MURRAY, A .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (04) :319-329
[7]  
KESTER RC, 1981, PRACTICE VASCULAR SU
[8]  
MCCLELLAND JL, 1988, HDB MODELS PROGRAMS
[9]  
Nichols WV, 1990, MCDONALDS BLOOD FLOW
[10]  
WILLIS MJ, 1990, SOLVING PROCESS ENG, P123