A NONLINEAR MODEL OF THE ARTERIAL SYSTEM INCORPORATING A PRESSURE-DEPENDENT COMPLIANCE

被引:57
作者
LI, JKJ
CUI, T
DRZEWIECKI, GM
机构
[1] Cardiovascular Research Laboratories, Department of Biomedical Engineering, Rutgers University, Piscataway
关键词
D O I
10.1109/10.55678
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The three-element modified Windkessel model has been widely used to study the characteristics of the systemic arterial system. This model.provides most of the features of the systemic input impedance, but does not describe the nonlinear effect of the pressure dependence of arterial compliance. The current investigation examines the hemodynamic consequences of such an inclusion. Simultaneous aortic pressure and flow during control and brief descending aortic occlusion were measured in open chest anesthetized experimental dogs. A numerical procedure was implemented to compute constant compliance linear and nonlinear compliance model-predicted pressure waveforms with flow as the input. Results show that the nonlinear compliance model in general can more accurately predict the measured pressure waveforms during control and during acute pressure loading. The difference between the predicted waveforms is more pronounced when blood pressure is high and when the pulse pressure is large. © 1990 IEEE
引用
收藏
页码:673 / 678
页数:6
相关论文
共 20 条
[11]  
LI JKJ, 1986, 7TH P INT C CARD SYS, V7, P1
[12]   ESTIMATION OF TOTAL ARTERIAL COMPLIANCE - AN IMPROVED METHOD AND EVALUATION OF CURRENT METHODS [J].
LIU, ZR ;
BRIN, KP ;
YIN, FCP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (03) :H588-H600
[13]  
NOORDERGRAAF A, 1978, CIRCULATORY SYSTEM D
[14]  
OROURKE MF, 1970, CIRC RES, V27, pI123
[15]   SYSTEMIC COMPLIANCE - DOES IT PLAY A ROLE IN THE GENESIS OF ESSENTIAL-HYPERTENSION [J].
RANDALL, OS ;
VANDENBOS, GC ;
WESTERHOF, N ;
POT, FOM .
CARDIOVASCULAR RESEARCH, 1984, 18 (08) :455-462
[16]  
SAFAR ME, 1984, HYPERTENSION, V6, P117
[17]   Pressure dependence of the canine aortic characteristic impedance and the effects of alterations in smooth muscle activity [J].
Stone, D.N. ;
Dujardin, J.-P.L. .
Medical and Biological Engineering and Computing, 1985, 23 (04) :324-328
[18]   EFFECTS OF DECREASED AORTIC COMPLIANCE ON PERFORMANCE OF LEFT VENTRICLE [J].
URSCHEL, CW ;
COVELL, JW ;
SONNENBLICK, EH ;
ROSS, J ;
BRAUNWALD, E .
AMERICAN JOURNAL OF PHYSIOLOGY, 1968, 214 (02) :298-+
[19]  
WANG PR, 1986, 39TH P ANN C ENG MED, V28, P246
[20]   ARTIFICIAL ARTERIAL SYSTEM FOR PUMPING HEARTS [J].
WESTERHOF, N ;
ELZINGA, G ;
SIPKEMA, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (05) :776-+