MR DETECTION OF LEAKAGE FROM SILICONE BREAST IMPLANTS - VALUE OF A SILICONE-SELECTIVE PULSE SEQUENCE

被引:44
作者
MONTICCIOLO, DL
NELSON, RC
DIXON, WT
BOSTWICK, J
MUKUNDAN, S
HESTER, TR
机构
[1] EMORY UNIV,SCH MED,FREDERICK PHILIPS MAGNET RESONANCE RES CTR,ATLANTA,GA 30322
[2] EMORY UNIV,SCH MED,DEPT SURG,ATLANTA,GA 30322
关键词
D O I
10.2214/ajr.163.1.8010247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the value of MR imaging with a silicone-selective pulse sequence for detecting leakage from silicone breast implants. SUBJECTS AND METHODS. Women with silicone breast implants were referred for this study on the basis of clinical or imaging findings suggestive of implant rupture. Twenty-eight patients with 38 implants were examined with silicone-selective MR imaging and also underwent surgical removal of the studied implant. All but four also had mammography before MR imaging. Results of silicone-selective MR imaging for the detection of silicone leakage were compared with mammographic and surgical findings. Surgical proof was considered the gold standard. RESULTS. Silicone-selective MR imaging showed an apparently intact implant in 21 cases; 20 of these were found to be intact at surgery, Silicone-selective MR imaging showed evidence of leakage in 17 implants, all of which showed leakage at surgery. The sensitivity for detection of leakage was 94%; the specificity was 100%. The findings of silicone-selective MR imaging and mammography were in agreement in 30 of 34 cases in which both studies were performed. In the four cases of disagreement, surgical findings agreed with MR findings in three and with mammographic findings in one. When the findings of mammography and silicone-selective MR imaging were combined, the correct status (leakage or no leakage) of all implants examined was determinable. CONCLUSION. Silicone-selective MR imaging is highly effective for detecting leakage from silicone breast implants, Accuracy is improved when mammographic and MR findings are considered together.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 13 条
  • [1] BREM RF, 1992, J COMPUT ASSIST TOMO, V16, P157
  • [2] MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE
    BYDDER, GM
    YOUNG, IR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 659 - 675
  • [3] SCREENING MAMMOGRAPHY IN 350 WOMEN WITH BREAST IMPLANTS - PREVALENCE AND FINDINGS OF IMPLANT COMPLICATIONS
    DESTOUET, JM
    MONSEES, BS
    OSER, RF
    NEMECEK, JR
    YOUNG, VL
    PILGRAM, TK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (05) : 973 - 978
  • [4] AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND
    GANOTT, MA
    HARRIS, KM
    ILKHANIPOUR, ZS
    COSTAGRECO, MA
    [J]. RADIOGRAPHICS, 1992, 12 (02) : 281 - 295
  • [5] SILICONE BREAST IMPLANTS INVIVO - MR IMAGING
    GORCZYCA, DP
    SINHA, S
    AHN, CY
    DEBRUHL, ND
    HAYES, MK
    GAUSCHE, VR
    SHAW, WW
    BASSETT, LW
    [J]. RADIOLOGY, 1992, 185 (02) : 407 - 410
  • [6] SOLVENT SUPPRESSION IN FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE
    HORE, PJ
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1983, 55 (02) : 283 - 300
  • [7] JENSEN SR, 1985, AM J ROENTGENOL, V144, P629
  • [8] MR-IMAGING OF SILICONE GEL - FILLED BREAST IMPLANTS IN-VIVO WITH A METHOD THAT VISUALIZES SILICONE SELECTIVELY
    MUKUNDAN, S
    DIXON, WT
    KRUSE, BD
    MONTICCIOLO, DL
    NELSON, RC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 713 - 717
  • [9] SELECTIVE MR IMAGING OF SILICONE WITH THE 3-POINT DIXON TECHNIQUE
    SCHNEIDER, E
    CHAN, TW
    [J]. RADIOLOGY, 1993, 187 (01) : 89 - 93
  • [10] PHANTOM EVALUATION OF IMAGING MODALITIES FOR SILICONE BREAST IMPLANTS
    STEINBACH, BG
    HISKES, SK
    FITZSIMMONS, JR
    LANIER, L
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (10) : 841 - 846