ACTIVE CURRENT ELECTRODES FOR IN-VIVO ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:20
作者
JOSSINET, J
TOURTEL, C
JARRY, R
机构
[1] Inst. Nat. de la Sante et de la Recherche Medicale, Lyon
关键词
D O I
10.1088/0967-3334/15/2A/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The characterization of tissue by means of electrical impedance tomography requires accurate impedance measurements at relatively high frequencies. The present study describes the design and fabrication of broad-band, active, current electrodes for in vivo measurements. This approach eliminates the lead capacitances of the sourcing electrodes. The value of the resistors used were computed according to a protocol taking into account the constraints of a given application and the values and tolerances of the available components. Additional selection of the components further reduced the variability in circuit performance. The current sources designed according to the method described are usable at frequencies higher than 1 MHz, for differential load impedances up to 2000 OMEGA. The parallel output conductance for each active electrode is 0.85 muS+/-2%. The design method is valid for either adjacent or diametric drive, and can be applied to various applications by modifying the shape of the electrode.
引用
收藏
页码:A83 / A90
页数:8
相关论文
共 8 条
  • [1] QUANTITATIVE TECHNIQUE FOR BIO-ELECTRICAL SPECTROSCOPY
    JOSSINET, J
    LOBEL, A
    MICHOUDET, C
    SCHMITT, M
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (04): : 289 - 294
  • [2] A hardware design for imaging the electrical impedance of the breast
    Jossinet, J.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 25 - 28
  • [3] ELECTRODE CURRENT DETERMINATION FROM PROGRAMMABLE VOLTAGE SOURCES
    LIDGEY, FJ
    ZHU, QS
    MCLEOD, CN
    BRECKON, WR
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 43 - 46
  • [4] LIDGEY FJ, 1990, 1990 P CAEIT EEC WOR, P183
  • [5] MCADAMS ET, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P85
  • [6] A BROAD-BAND SYSTEM FOR MULTIFREQUENCY STATIC IMAGING IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RIU, PJ
    ROSELL, J
    LOZANO, A
    PALLASARENY, R
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 61 - 65
  • [7] ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEMS BASED ON VOLTAGE DRIVE
    SANSEN, W
    GEERAERTS, B
    VANPETEGEM, W
    STEYAERT, M
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 39 - 42
  • [8] THE PERFORMANCE OF INTEGRATED TRANSCONDUCTANCE AMPLIFIERS AS VARIABLE CURRENT SOURCES FOR BIO-ELECTRIC IMPEDANCE MEASUREMENTS
    SMITH, DN
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 25 - 30