PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN

被引:87
作者
SCHWARTZ, LH [1 ]
SELTZER, SE [1 ]
TEMPANY, CMC [1 ]
SILVERMAN, SG [1 ]
PIWNICAWORMS, DR [1 ]
ADAMS, DF [1 ]
HERMAN, L [1 ]
HERMAN, LT [1 ]
HOOSHMAND, R [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
LIVER NEOPLASMS; MAGNETIC RESONANCE (MR); PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.189.2.8210368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of fast spin-echo (FSE) magnetic resonance imaging with and without fat suppression in the liver and upper abdomen. MATERIALS AND METHODS: Conventional spin-echo (SE) T2-weighted, FSE T2-weighted, and fat-suppressed FSE T2-weighted images from 37 patients strongly suspected to have focal hepatic lesions were evaluated. RESULTS: Quantitative analysis demonstrated that fat-suppressed FSE imaging had the highest lesion-liver contrast-to-noise ratio; conventional SE imaging, the lowest. In a qualitative analysis, FSE imaging was preferred. In a rank order analysis, FSE imaging was preferred 83% of the time and fat-suppressed FSE imaging 17% of the time as regards overall image quality; fat-suppressed FSE imaging was preferred 64% of the time, FSE imaging 23% of the time, and conventional SE imaging 13% of the time as regards signal abnormality detection. CONCLUSION: FSE imaging with and without fat suppression is a potentially useful pulse sequence for evaluating the upper abdomen.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 22 条
[1]   SHORT TI INVERSION-RECOVERY IMAGING OF THE LIVER - PULSE-SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO IMAGING [J].
DOUSSET, M ;
WEISSLEDER, R ;
HENDRICK, RE ;
STARK, DD ;
FRETZ, CJ ;
ELIZONDO, G ;
HAHN, PF ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1989, 171 (02) :327-333
[2]   HEPATIC-TUMORS - QUANTITATIVE TISSUE CHARACTERIZATION WITH MR IMAGING [J].
EGGLIN, TK ;
RUMMENY, E ;
STARK, DD ;
WITTENBERG, J ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 176 (01) :107-110
[3]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[4]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[5]   DIFFERENTIATION BETWEEN SMALL HEPATIC HEMANGIOMAS AND METASTASES ON MR IMAGES - IMPORTANCE OF SIZE-SPECIFIC QUANTITATIVE CRITERIA [J].
ITOH, K ;
SAINI, S ;
HAHN, PF ;
IMAM, N ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (01) :61-66
[6]   FAST SPIN-ECHO MR IMAGING OF THE BRAIN AND SPINE - CURRENT CONCEPTS [J].
JONES, KM ;
MULKERN, RV ;
SCHWARTZ, RB ;
OSHIO, K ;
BARNES, PD ;
JOLESZ, FA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (06) :1313-1320
[7]   ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING [J].
LOW, RN ;
FRANCIS, IR ;
SIGETI, JS ;
FOO, TKF .
RADIOLOGY, 1993, 186 (03) :803-811
[8]   COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES [J].
MELKI, PS ;
MULKERN, RV ;
PANYCH, LP ;
JOLESZ, FA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :319-326
[9]   MOTION ARTIFACT REDUCTION IN MR IMAGING OF THE ABDOMEN - GRADIENT MOMENT NULLING VERSUS RESPIRATORY-SORTED PHASE ENCODING [J].
MITCHELL, DG ;
VINITSKI, S ;
BURK, DL ;
LEVY, DW ;
RIFKIN, MD .
RADIOLOGY, 1988, 169 (01) :155-160
[10]   LIVER AND PANCREAS - IMPROVED SPIN-ECHO T1 CONTRAST BY SHORTER ECHO TIME AND FAT SUPPRESSION AT 1.5-T [J].
MITCHELL, DG ;
VINITSKI, S ;
SAPONARO, S ;
TASCIYAN, T ;
BURK, DL ;
RIFKIN, MD .
RADIOLOGY, 1991, 178 (01) :67-71