PROFILING OF ARACHIDONIC-ACID METABOLITES IN RABBIT PLATELETS BY RADIO GAS-CHROMATOGRAPHY

被引:4
作者
AKIRA, K [1 ]
NAKAMURA, T [1 ]
SHINOHARA, Y [1 ]
BABA, S [1 ]
机构
[1] TOKYO COLL PHARM,1432-1 HORINOUCHI,HACHIOJI,TOKYO 19203,JAPAN
关键词
D O I
10.1007/BF02536324
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method for profiling arachidonic acid metabolites by radio gas chromatography (GC) is described. The incubation mixture of rabbit platelets with [C-14]arachidonic acid was purified on a Sep-Pak C18 cartridge and derivatized with diazomethane, O-methylhydroxylamine and dimethylisopropylsilylimidazole. The recovery of total C-14-radioactivity was 93.1 +/- 7.2%. Loss of radioactivity during derivatization was negligible. Baseline separations for [C-14]arachidonic acid and its metabolites were obtained in a single run within 45 min by GC using a synchronized accumulating radioisotope detector (GC/SARD). The recovery of radioactivity from the GC column was virtually 100%. The chemical structures of the metabolites were confirmed by GC/mass spectrometry; peaks of arachidonic acid metabolites were assigned by comparison of the methylene unit values with those of radioactive peaks in GC/SARD analyses. The intra-assay coefficients of variation in GC/SARD analyses were less than 10%. The method was used to map the profile of arachidonic acid metabolites formed by rabbit platelets in the presence of indomethacin, baicalein or glutathione.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 34 条
  • [1] GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC FRACTIONS REFLECTING ARACHIDONIC-ACID METABOLISM IN MOUSE PERITONEAL-MACROPHAGES
    ABIAN, J
    BIOQUE, G
    BULBENA, O
    ROSELLO, J
    GELPI, E
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (02) : 69 - 79
  • [2] RADIO-GAS CHROMATOGRAPHY ON WIDE-BORE CAPILLARY COLUMNS EQUIPPED WITT A SYNCHRONIZED ACCUMULATING RADIOISOTOPE DETECTOR
    AKIRA, K
    BABA, S
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (01): : 21 - 31
  • [3] IMPROVED SYNCHRONIZED ACCUMULATING RADIOISOTOPE DETECTOR FOR GAS-CHROMATOGRAPHY
    AKIRA, K
    BABA, S
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (02): : 255 - 262
  • [4] SYNCHRONIZED ACCUMULATING RADIOISOTOPE DETECTOR FOR RADIO GAS-CHROMATOGRAPHY
    BABA, S
    KASUYA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 196 (01): : 144 - 149
  • [5] RADIO-GAS CHROMATOGRAPHY
    BABA, S
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 492 : 137 - 165
  • [6] APPLICATION OF RADIOISOTOPE TRACER TECHNIQUES TO ANALYTICAL GAS-CHROMATOGRAPHY - DETERMINATION OF GAS-CHROMATOGRAPHIC PEAK YIELD
    BABA, S
    AKIRA, K
    HORIE, M
    MORI, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 341 (02): : 251 - 259
  • [7] USE OF RADIO-GAS CHROMATOGRAPHY AND TRITIUM LABEL TO OPTIMIZE DERIVATIZATION PROCEDURES
    BABA, S
    AKIRA, K
    SEYAMA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01): : 1 - 9
  • [8] BABA S, 1993, IN PRESS CRC HDB CHR
  • [9] BIRKLE DL, 1988, PROGR HPLC, V3, P11
  • [10] ISOLATION OF A NEW LIPOXYGENASE METABOLITE OF ARACHIDONIC-ACID, 8,11,12-TRIHYDROXY-5,9,14-EICOSATRIENOIC ACID FROM HUMAN PLATELETS
    BRYANT, RW
    BAILEY, JM
    [J]. PROSTAGLANDINS, 1979, 17 (01): : 9 - 18