RETENTION BEHAVIOR OF SOME RING-SUBSTITUTED ANILINE DERIVATIVES ON POLYETHYLENE-COATED AND OCTADECYLSILICA COLUMNS

被引:12
作者
FORGACS, E
机构
[1] Central Research Institute for Chemistry Hungarian Academy of Sciences, Budapest
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 17期
关键词
D O I
10.1080/10826079308019665
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The retention characteristics of 16 aniline derivatives were determined on polyethylene-coated and on octadecylsilica columns in methanol-25 mM K2HPO4 mixtures at various organic phase concentrations. Good linear correlations were found on both column between logk' values and the organic mobile phase concentration in the eluent. Stepwise regression analysis proved that not only lipophilicity but electronic parameters of aniline derivatives have significant influence on the retention of aniline derivatives on polyethylene-coated silica column. Principal component analysis indicated that the retention behaviour of PEE column slightly differs from that of ODS column. This discrepancy is probably due to the hydrophobic interactions between the-polar substructures of aniline derivatives and the free silanol groups not-covered by polyethylene.
引用
收藏
页码:3757 / 3772
页数:16
相关论文
共 16 条
[1]   HIGH-PERFORMANCE HYDROPHOBIC-INTERACTION CHROMATOGRAPHY OF PROTEINS ON A SERIES OF POLY(ALKYL ASPARTAMIDE)-SILICAS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :85-97
[2]  
ALPERT AJ, 1988, J CHROMATOGR, V433, P85
[3]   CHEMICALLY BONDED PHASES FOR THE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BASIC SUBSTANCES [J].
BUSZEWSKI, B ;
SCHMID, J ;
ALBERT, K ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2) :415-427
[4]  
CSERHATI T, 1984, J CHROMATOGR, V287, P386
[5]   STATIONARY PHASES FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY - COATING OF SILICA BY POLYMERS OF VARIOUS POLARITIES [J].
FIGGE, H ;
DEEGE, A ;
KOHLER, J ;
SCHOMBURG, G .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (03) :393-408
[6]  
HAGER H, 1992, MODERN REGRESSIONALA
[7]  
HAILIN G, 1991, J CHROMATOGR, V588, P25
[8]  
HANSEN M, 1992, J CHROMATOGR, V559, P65
[9]   POLYMER-COATED REVERSED-PHASE PACKINGS WITH CONTROLLED HYDROPHOBIC PROPERTIES .2. EFFECT ON THE SELECTIVITY OF PEPTIDE SEPARATIONS [J].
HANSON, M ;
UNGER, KK ;
MANT, CT ;
HODGES, RS .
JOURNAL OF CHROMATOGRAPHY, 1992, 599 (1-2) :77-85
[10]   EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .6. DESIGN, CHROMATOGRAPHIC PERFORMANCE AND APPLICATION OF NON-POROUS SILICA-BASED ANION-EXCHANGERS [J].
JILGE, G ;
UNGER, KK ;
ESSER, U ;
SCHAFER, HJ ;
RATHGEBER, G ;
MULLER, W .
JOURNAL OF CHROMATOGRAPHY, 1989, 476 :37-48