A ONE-STEP SANDWICH ENZYME-IMMUNOASSAY FOR HUMAN MATRIX METALLOPROTEINASE-3 (STROMELYSIN-1) USING MONOCLONAL-ANTIBODIES

被引:119
作者
OBATA, K
IWATA, K
OKADA, Y
KOHRIN, Y
OHUCHI, E
YOSHIDA, S
SHINMEI, M
HAYAKAWA, T
机构
[1] FUJI CHEM IND CO LTD,RES INST,DEPT BIOTECHNOL,530 CHOKEIJI TAKAOKA,TOYAMA 933,JAPAN
[2] KANAZAWA UNIV,SCH MED,DEPT PATHOL,KANAZAWA,ISHIKAWA 920,JAPAN
[3] NATL DEF MED COLL,DEPT ORTHOPAED SURG,TOKOROZAWA,SAITAMA 359,JAPAN
[4] AICHI GAKUIN UNIV,SCH DENT,DEPT BIOCHEM,NAGOYA,AICHI,JAPAN
关键词
SANDWICH ENZYME IMMUNOASSAY; STROMELYSIN-1; MONOCLONAL ANTIBODY; RHEUMATOID ARTHRITIS; OSTEOARTHRITIS;
D O I
10.1016/0009-8981(92)90105-Y
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A one-step sandwich enzyme immunoassay (EIA) for matrix metalloproteinase 3 (MMP-3; stromelysin-1) was developed. The assay system used two simultaneous immunoreactions using a solid phase monoclonal antibody and a horseradish peroxidase-labeled monoclonal antibody (Fab'). The sensitivity of the assay system was 20 mug/l and linearity was obtained between 31 and 500 mug/l. The EIA system was capable of measuring both precursor and active forms of MMP-3 as well as the forms of MMP-3 complexed with tissue inhibitors of metalloproteinases. MMP-3 levels as measured by this assay are significantly higher in the sera of patients with rheumatoid arthritis as compared to those of healthy subjects and patients with osteoarthritis. Immunoblot analyses showed that in the sera and synovial fluids of patients with rheumatoid arthritis, MMP-3 is present in the 59- and 57-kDa precursor forms.
引用
收藏
页码:59 / 72
页数:14
相关论文
共 33 条
  • [1] EVIDENCE FOR PRESENCE OF A COMPLEX OF COLLAGENASE WITH ALPHA2-MACROGLOBULIN IN HUMAN RHEUMATOID SYNOVIAL-FLUID - POSSIBLE REGULATORY MECHANISM OF COLLAGENASE ACTIVITY IN-VIVO
    ABE, S
    NAGAI, Y
    [J]. JOURNAL OF BIOCHEMISTRY, 1973, 73 (04) : 897 - 900
  • [2] DEVELOPMENT OF CRITERIA FOR THE CLASSIFICATION AND REPORTING OF OSTEOARTHRITIS - CLASSIFICATION OF OSTEOARTHRITIS OF THE KNEE
    ALTMAN, R
    ASCH, E
    BLOCH, D
    BOLE, G
    BORENSTEIN, D
    BRANDT, K
    CHRISTY, W
    COOKE, TD
    GREENWALD, R
    HOCHBERG, M
    HOWELL, D
    KAPLAN, D
    KOOPMAN, W
    LONGLEY, S
    MANKIN, H
    MCSHANE, DJ
    MEDSGER, T
    MEENAN, R
    MIKKELSEN, W
    MOSKOWITZ, R
    MURPHY, W
    ROTHSCHILD, B
    SEGAL, M
    SOKOLOFF, L
    WOLFE, F
    [J]. ARTHRITIS AND RHEUMATISM, 1986, 29 (08): : 1039 - 1049
  • [3] THE AMERICAN-RHEUMATISM-ASSOCIATION 1987 REVISED CRITERIA FOR THE CLASSIFICATION OF RHEUMATOID-ARTHRITIS
    ARNETT, FC
    EDWORTHY, SM
    BLOCH, DA
    MCSHANE, DJ
    FRIES, JF
    COOPER, NS
    HEALEY, LA
    KAPLAN, SR
    LIANG, MH
    LUTHRA, HS
    MEDSGER, TA
    MITCHELL, DM
    NEUSTADT, DH
    PINALS, RS
    SCHALLER, JG
    SHARP, JT
    WILDER, RL
    HUNDER, GG
    [J]. ARTHRITIS AND RHEUMATISM, 1988, 31 (03): : 315 - 324
  • [4] BARRETT AJ, 1981, METHOD ENZYMOL, V80, P735
  • [5] Bos E S, 1981, J Immunoassay, V2, P187, DOI 10.1080/15321818108056977
  • [6] IMMUNOASSAYS FOR THE DETECTION OF HUMAN COLLAGENASE, STROMELYSIN, TISSUE INHIBITOR OF METALLOPROTEINASES (TIMP) AND ENZYME-INHIBITOR COMPLEXES
    COOKSLEY, S
    HIPKISS, JB
    TICKLE, SP
    HOLMESIEVERS, E
    DOCHERTY, AJP
    MURPHY, G
    LAWSON, ADG
    [J]. MATRIX, 1990, 10 (05): : 285 - 291
  • [7] DECLERCK YA, 1989, J BIOL CHEM, V264, P17445
  • [8] ENGHILD JJ, 1989, J BIOL CHEM, V264, P8779
  • [9] ISOLATION OF PURE IGG1, IGG2A AND IGG2B IMMUNOGLOBULINS FROM MOUSE SERUM USING PROTEIN A-SEPHAROSE
    EY, PL
    PROWSE, SJ
    JENKIN, CR
    [J]. IMMUNOCHEMISTRY, 1978, 15 (07): : 429 - 436
  • [10] HUMAN 72-KILODALTON TYPE-IV COLLAGENASE FORMS A COMPLEX WITH A TISSUE INHIBITOR OF METALLOPROTEASES DESIGNATED TIMP-2
    GOLDBERG, GI
    MARMER, BL
    GRANT, GA
    EISEN, AZ
    WILHELM, S
    HE, CS
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (21) : 8207 - 8211