PROLONGED INTRAUTERINE CONTRACEPTION - A 7-YEAR RANDOMIZED STUDY OF THE LEVONORGESTREL 20 MCG/DAY (LNG-20) AND THE COPPER T380 AG IUDS

被引:171
作者
SIVIN, I
STERN, J
COUTINHO, E
MATTOS, CER
ELMAHGOUB, S
DIAZ, S
PAVEZ, M
ALVAREZ, F
BRACHE, V
THEVENIN, F
DIAZ, J
FAUNDES, A
DIAZ, MM
MCCARTHY, T
MISHELL, DR
SHOUPE, D
机构
[1] UNIV FED BAHIA, FAC MED MATERNIDADE CLIMERO OLIVEIRA, SALVADOR, BA, BRAZIL
[2] AIN SHAMS UNIV, DEPT OBSTET & GYNECOL, CAIRO, EGYPT
[3] INST CHILENO MED REPROD, SANTIAGO, CHILE
[4] PROFAMILIA, SANTO DOMINGO, DOMINICAN REP
[5] CTR PESQUISAS & CONTROLE DOENCAS MATERNOINFANTIS C, CAMPINAS, SP, BRAZIL
[6] NATL UNIV SINGAPORE, DEPT OBSTET & GYNECOL, SINGAPORE, SINGAPORE
[7] UNIV SO CALIF, SCH MED, DEPT OBSTET & GYNECOL, LOS ANGELES, CA 90033 USA
基金
美国安德鲁·梅隆基金会;
关键词
D O I
10.1016/0010-7824(91)90149-A
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
A levonorgestrel-releasing IUD and the Copper T 380Ag IUD were in randomized comparison for seven years in five clinics. In two other clinics the randomized study was truncated at five years, but use of the Copper T continued. No pregnancies occurred to users of either device in years 6 and 7. Cumulative pregnancy rates were 1.1 per 100 at seven years for the steroid-releasing and 1.4 per 100 for the copper-releasing IUDs. Cumulative rates of PID did not differ between devices. Infection rates appeared to be lowest during the sixth and seventh years of the study. Termination attributable to amenorrhea was the principal contributor to differences in cumulative continuation rates between devices. At the five clinics that carried the comparative study to seven years, cumulative continuation rates were 24.9 per 100 for LNg20 IUD users and 29.4 per 100 for TCu 380Ag users. Women who used either method for periods of five to seven years experienced, on average, marked to mild increases in hemoglobin as compared with levels at admission. The Copper T380 family and the LNg20 IUDs represent the most effective reversible contraceptive methods yet studied in long-term randomized trials.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 11 条
[1]   QUANTITATIVE STUDIES ON MENSTRUAL BLOOD-LOSS IN IUD USERS [J].
ANDRADE, ATL ;
ORCHARD, EP .
CONTRACEPTION, 1987, 36 (01) :129-144
[2]   RECOVERY OF FERTILITY AFTER USE OF THE LEVONORGESTREL 20 MCG/D OR COPPER T-380 AG INTRAUTERINE-DEVICE [J].
BELHADJ, H ;
SIVIN, I ;
DIAZ, S ;
PAVEZ, M ;
TEJADA, AS ;
BRACHE, V ;
ALVAREZ, F ;
SHOUPE, D ;
BREAUX, H ;
MISHELL, DR ;
MCCARTHY, T ;
YO, V .
CONTRACEPTION, 1986, 34 (03) :261-267
[3]  
EDELMAN DA, 1990, BR J FAM PLAN, V16, P132
[4]   LIFE-TABLE ANALYSIS OF IUDS - PROBLEMS AND RECOMMENDATIONS [J].
JAIN, AK ;
SIVIN, I .
STUDIES IN FAMILY PLANNING, 1977, 8 (02) :25-47
[5]  
ROWE PJ, 1990, CONTRACEPTION, V42, P141
[6]  
SAXENA BN, 1989, CONTRACEPTION, V39, P37
[7]   LONG-TERM CONTRACEPTION WITH THE LEVONORGESTREL 20 MCG/DAY (LNG 20) AND THE COPPER-T 380AG INTRAUTERINE-DEVICES - A 5-YEAR RANDOMIZED STUDY [J].
SIVIN, I ;
ELMAHGOUB, S ;
MCCARTHY, T ;
MISHELL, DR ;
SHOUPE, D ;
ALVAREZ, F ;
BRACHE, V ;
JIMENEZ, E ;
DIAZ, J ;
FAUNDES, A ;
DIAZ, MM ;
COUTINHO, E ;
MATTOS, CER ;
DIAZ, S ;
PAVEZ, M ;
STERN, J .
CONTRACEPTION, 1990, 42 (04) :361-378
[8]   2 YEARS OF INTRAUTERINE CONTRACEPTION WITH LEVONORGESTREL AND WITH COPPER - A RANDOMIZED COMPARISON OF THE TCU 380AG AND LEVONORGESTREL 20 MCG/DAY DEVICES [J].
SIVIN, I ;
STERN, J ;
DIAZ, J ;
DIAZ, MM ;
FAUNDES, A ;
ELMAHGOUB, S ;
DIAZ, S ;
PAVEZ, M ;
COUTINHO, E ;
MATTOS, CER ;
MCCARTHY, T ;
MISHELL, DR ;
SHOUPE, D ;
ALVAREZ, F ;
BRACHE, V ;
JIMENEZ, E .
CONTRACEPTION, 1987, 35 (03) :245-255
[9]   INTRAUTERINE CONTRACEPTION WITH COPPER AND WITH LEVONORGESTREL - A RANDOMIZED STUDY OF THE TCU 380AG AND LEVONORGESTREL 20 MCG/DAY DEVICES [J].
SIVIN, I ;
ALVAREZ, F ;
DIAZ, J ;
DIAZ, S ;
ELMAHGOUB, S ;
COUTINHO, E ;
BRACHE, V ;
DIAZ, MM ;
FAUNDES, A ;
PAVEZ, M ;
MATTOS, CER ;
STERN, J .
CONTRACEPTION, 1984, 30 (05) :443-456
[10]  
STADEL BV, 1984, OBSTET GYNECOL, V63, P171