BIVARIATE FLOW KARYOTYPING WITH AIR-COOLED LASERS

被引:6
作者
FREY, T [1 ]
HOUCK, DW [1 ]
SHENKER, BJ [1 ]
HOFFMAN, RA [1 ]
机构
[1] UNIV PENN,SCH DENT MED,DEPT PATHOL,PHILADELPHIA,PA 19104
来源
CYTOMETRY | 1994年 / 16卷 / 02期
关键词
CHROMOSOME; HELIUM-CADMIUM LASER; FLOW CYTOMETRY; THIAZOLE ORANGE;
D O I
10.1002/cyto.990160211
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An experimental flow cytometer was constructed using a quartz flow cell optically coupled to a 1.22 NA lens. A pair of crossed cylindrical quartz lenses allowed multilaser excitation. Two helium-cadmium (HeCd) lasers, emitting 16 mW at 442 nm and 35 mW at 325 nm, were used to excite chromomycin A3 and Hoechst 33258 fluorescence, respectively. Bivariate flow karyotypes from normal human male chromosomes and from the Daudi cell line were obtained and were compared to those from a standard instrument using dual water-cooled lasers. The new experimental instrument exhibited comparable resolution to that from the standard instrument. In further experiments with Daudi chromosomes, the 35 mW HeCd laser was replaced with a 10 mW HeCd laser, and the system still gave good, though slightly decreased, resolution. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 13 条
[1]   A COMPARISON OF LOW-POWER HELIUM-CADMIUM AND ARGON ULTRAVIOLET-LASERS IN COMMERCIAL FLOW CYTOMETERS [J].
BIGLER, RD .
CYTOMETRY, 1987, 8 (05) :441-444
[2]  
Cram L S, 1990, Methods Cell Biol, V33, P377
[3]  
CRAM LS, 1989, FLOW CYTOGENETICS, P113
[4]   UV LASERS FOR FLOW CYTOMETRIC ANALYSIS - HECD VERSUS ARGON-LASER EXCITATION [J].
GOLLER, B ;
KUBBIES, M .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1992, 40 (04) :451-456
[5]   CHROMOSOME MEASUREMENT AND SORTING BY FLOW SYSTEMS [J].
GRAY, JW ;
CARRANO, AV ;
STEINMETZ, LL ;
VANDILLA, MA ;
MOORE, DH ;
MAYALL, BH ;
MENDELSOHN, ML .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1975, 72 (04) :1231-1234
[6]  
JENSENRH, 1977, J HISTOCHEM CYTOCHEM, V25, P954
[7]  
KLEIN E, 1968, CANCER RES, V28, P1300
[8]   IMPROVED BRDURD-HOECHST BIVARIATE CELL KINETIC-ANALYSIS BY HELIUM-CADMIUM SINGLE LASER EXCITATION [J].
KUBBIES, M ;
GOLLER, B ;
VANBOCKSTAELE, DR .
CYTOMETRY, 1992, 13 (07) :782-786
[9]   ACTIVE ANALOG PIPELINE DELAYS FOR HIGH SIGNAL RATES IN MULTISTATION FLOW CYTOMETERS [J].
PARSON, JD ;
HIEBERT, RD ;
MARTIN, JC .
CYTOMETRY, 1985, 6 (04) :388-391
[10]   CYTOMAT-R - COMPUTER-CONTROLLED MULTIPLE LASER SOURCE MULTIPARAMETER FLOW CYTOPHOTOMETER SYSTEM [J].
SHAPIRO, HM ;
SCHILDKRAUT, ER ;
CURBELO, R ;
TURNER, RB ;
WEBB, RH ;
BROWN, DC ;
BLOCK, MJ .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1977, 25 (07) :836-844