IN-VIVO SAMPLE UPTAKE AND ONLINE MEASUREMENTS OF COBALT IN WHOLE-BLOOD BY MICROWAVE-ASSISTED MINERALIZATION AND FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY - PUBLISHED IN CELEBRATION OF THE 10TH ANNIVERSARY

被引:20
作者
BURGUERA, M
BURGUERA, JL
RONDON, C
RIVAS, C
CARRERO, P
GALLIGNANI, M
BRUNETTO, MR
机构
关键词
COBALT; WHOLE BLOOD; ONLINE MINERALIZATION; MICROWAVE-OVEN MINERALIZATION; FLOW INJECTION; ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY;
D O I
10.1039/ja9951000343
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line automated microwave-assisted mineralization and Bow injection system was developed for the determination of cobalt in whole blood with in vivo sample uptake by electrothermal atomic absorption spectrometry, The samples were drawn and at the same time pumped directly from the vein of a patient's forearm to a timed injector, which is automatically controlled to inject the sample-nitric acid-anticoagulant mixture into the carrier stream. Volumes (20 mu l) of the mineralized samples, collected in a capillary of a sampling arm assembly, were introduced by means of positive displacement with air through a time-based solenoid injector (TBSI) into the graphite tube atomizer, The spectrometer autosampler, used for the introduction of 10 mu l of the chemical modifier, magnesium nitrate, and the furnace programme were re-programmed to synchronize with the operation of the flow system, The linear range was from 0 to 50 mu g l(-1) of cobalt, achieving a precision of 2.6 and 3.1% for 10 replicate analyses of a 5 mu g l(-1) cobalt standard solution and a certified sample, respectively, with a detection limit of 0.3 mu g l(-1). The agreement between the observed and certified values obtained from Seronorm Whole Blood Standard Reference Materials was good, The results obtained by using an in-batch procedure were found to linearly increase by 5% during the time interval; between sample collection and analysis for the first hour; after this time the results for cobalt levelled off and mere then in close agreement with those obtained by the on-line procedure proposed here.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 37 条
[1]   DETERMINATION OF COBALT IN BLOOD [J].
BARFOOT, RA ;
PRITCHARD, JG .
ANALYST, 1980, 105 (1251) :551-557
[2]  
BLANCHFLOWER WJ, 1990, ANALYST, V115, P1322
[3]  
Burguera J. L., 1991, Laboratory Robotics and Automation, V3, P119
[4]  
BURGUERA JL, 1993, ATOM SPECTROSC, V14, P90
[5]   DETERMINATION OF LEAD IN BIOLOGICAL-MATERIALS BY MICROWAVE-ASSISTED MINERALIZATION AND FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :235-241
[6]  
BURGUERA JL, 1994, IN PRESS ANAL CHIM A
[7]   FLOW-INJECTION AND MICROWAVE-OVEN SAMPLE DECOMPOSITION FOR DETERMINATION OF COPPER, ZINC AND IRON IN WHOLE-BLOOD BY ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, M ;
BURGUERA, JL ;
ALARCON, OM .
ANALYTICA CHIMICA ACTA, 1986, 179 :351-357
[8]  
BURGUERA M, 1993, LAB ROBOTICS AUTOMAT, V5, P1
[9]   DETERMINATION OF COBALT IN HUMAN LIVER BY ATOMIC-ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION [J].
CALDAS, ED ;
GINEROSIAS, MF ;
DOREA, JG .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :113-118
[10]   ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS OF SOLIDS WITH ONLINE MICROWAVE-ASSISTED DIGESTION [J].
CARBONELL, V ;
MORALESRUBIO, A ;
SALVADOR, A ;
DELAGUARDIA, M ;
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1085-1089