VARIABLE FLIP ANGLE IMAGING AND FAT SUPPRESSION IN COMBINED GRADIENT AND SPIN-ECHO (GREASE) TECHNIQUES

被引:20
作者
VINITSKI, S
MITCHELL, DG
SZUMOWSKI, J
BURK, DL
RIFKIN, MD
机构
[1] Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA
[2] Jefferson Medical College, Department of Radiology, Philadelphia, PA
[3] University of Rochester, Department of Radiology, Rochester, NY
关键词
Fast imaging; Fat suppression; Image contrast; Magnetic resonance imaging; Motion artifact;
D O I
10.1016/0730-725X(90)90246-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional "proton density" and "T2-weighted" spin-echo images are susceptible to motion induced artifact, which is exacerbated by lipid signals. Gradient moment nulling can reduce motion artifact but lengthens the minimum TE, degrading the "proton density" contrast. We designed a pulse sequence capable of optimizing proton density and T2-weighted contrast while suppressing lipid signals and motion induced artifacts. Proton density weighting was obtained by rapid readout gradient reversal immediately after the excitation RF pulse, within a conventional spin-echo sequence. By analyzing the behavior of the macroscopic magnetization and optimizing excitation flip angle, we suppressed T1 contribution to the image, thereby enhancing proton density and T2-weighted contrast with a two- to four-fold reduction of repetition time. This permitted an increased number of averages to be used, reducing motion induced artifacts. Fat suppression in the presence of motion was investigated in two groups of 8 volunteers each by (i) modified Dixon technique, (ii) selective excitation, and (iii) hybrid of both. Elimination of fat signal by the first technique was relatively uniform across the field of view, but it did not fully suppress the ghosts originating from fat motion. Selective excitation, while sensitive to the main field inhomogeneity, largely eliminated the ghosts (0.21 ± 0.05 vs. 0.29 ± 0.06, p < 0.01). The hybrid of both techniques combined with bandwidth optimization, however, showed the best results (0.17 ± 0.04, p < 0.001). Variable flip-angle imaging allows optimization of image contrast which, along with averaging and effective fat suppression, significantly improves gradient- and spin-echo imaging, particularly in the presence of motion. © 1990.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 33 条
[21]  
temperature
[22]  
species
[23]  
excision and age, Med. Phys., 11, pp. 425-448, (1984)
[24]  
Hart, Bottomley, Edelstein, Karr, Nuclear magnetic resonance imaging: Contrast to noise ratio as a function of strength of magnetic field, AJR, 141, pp. 1195-1201, (1983)
[25]  
Pelc, Shimakawa, A software approach to variable bandwidth multiecho imaging, Transplant Proc, (1988)
[26]  
Mugler, Brookman, Mixed bandwidth pulse sequences for MRI: Technical aspects, Magn. Reson. Imaging, 6, 1, (1988)
[27]  
Haase, Frahm, Hanicke, Matthaei, <sup>1</sup>H NMR chemical shift selective (CHESS) imaging, Phys. Med. Biol., 30, 4, pp. 341-344, (1985)
[28]  
Hore, Solvent suppression in Fourier transform nuclear magnetic resonance, J. Magn. Reson., 55, pp. 283-300, (1983)
[29]  
Dixon, Simple proton spectroscopic imaging, Radiology, 153, (1984)
[30]  
Szumowski, Plewes, Separation of lipid and water signals by chopper averaging in time domain, Radiology, 165, pp. 247-250, (1987)