COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY FOR THE FAST SEPARATION AND DETERMINATION OF PESTICIDES EXTRACTED FROM HUMAN SERUM

被引:96
作者
LIU, ZY
SIRIMANNE, SR
PATTERSON, DG
NEEDHAM, LL
PHILLIPS, JB
机构
[1] U.S. Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Environmental Health Laboratory Sciences, Toxicology Branch, Atlanta, Georgia 30341, 4770 Buford Highway, NE
[2] Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale
关键词
D O I
10.1021/ac00091a016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comprehensive two-dimensional gas chromatograph with name ionization detection was constructed and evaluated for the fast separation and analysis of pesticides. A two-stage thermal desorption modulator served as an interface between the two capillary GC columns. By controlling the temperature of the modulator chamber, all sample substances covering a wide polarity and volatility range were modulated without sample breakthrough. Orthogonal separations were achieved with a nonpolar first column and a moderately polar second column. The system allows fast separations of complex mixtures. When we used the method to analyze pesticides extracted from human samples, we achieved complete separation of 15 pesticides in less than 4 min. The flame ionization detector gave detection limits for particular pesticides that ranged from 1.8 to 3.8 pg on-column. The relative standard deviations were from 6.2% to 8.8% over the linear dynamic range.
引用
收藏
页码:3086 / 3092
页数:7
相关论文
共 11 条
[1]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[3]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - THEORY, COMPUTER-BASED TESTING, AND ANALYSIS OF ERRORS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2168-2177
[4]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323
[5]   2-DIMENSIONAL SEPARATIONS OF PEPTIDES AND PROTEINS BY COMPREHENSIVE LIQUID-CHROMATOGRAPHY CAPILLARY-ELECTROPHORESIS [J].
LARMANN, JP ;
LEMMO, AV ;
MOORE, AW ;
JORGENSON, JW .
ELECTROPHORESIS, 1993, 14 (5-6) :439-447
[6]   INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL CAPILLARY SUPERCRITICAL FLUID-GAS CHROMATOGRAPHY [J].
LIU, Z ;
OSTROVSKY, I ;
FARNSWORTH, PB ;
LEE, ML .
CHROMATOGRAPHIA, 1993, 35 (9-12) :567-573
[7]  
Liu Z, 1989, J MICROCOLUMN SEP, V1, P249
[8]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE [J].
LIU, ZY ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :227-231
[9]  
Phillips J. B., 1992, US Patent, Patent No. [5,135,549, 5135549]
[10]  
Phillips J. B., 1993, U.S. Patent, Patent No. [5,196,039, 5196039]