SEEDING EF INTRACORONARY STENTS WITH IMMORTALIZED HUMAN MICROVASCULAR ENDOTHELIAL-CELLS

被引:52
作者
SCOTT, NA [1 ]
CANDAL, FJ [1 ]
ROBINSON, KA [1 ]
ADES, EW [1 ]
机构
[1] CTR DIS CONTROL & PREVENT,BIOL PROD BRANCH,ATLANTA,GA 30341
关键词
D O I
10.1016/0002-8703(95)90104-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intracoronary stents are effective in decreasing the complications associated with acute closure during coronary angioplasty. A major complication associated with the use of coronary stents is acute thrombotic occlusion. it has been postulated that the stent loses its thrombogenic potential after it becomes covered with a layer of endothelial cells. Human dermal microvascular endothelial cells were transfected with a plasmid containing the simian virus 40 large T-antigen gene. Stents were placed in culture media with cells for 2 weeks. Seeding efficiency of the stent with the endothelial cells was assessed by scanning electron microscopy. Balloon-expandable coronary stents placed in cell culture with immortalized human microvascular endothelial cells showed near-complete coverage after 2 weeks. After balloon inflation, persistence of cells on the stent was noted only on the lateral aspect of the balloon-expanded stents. If these stents were placed in culture, complete recovery of the monolayer was noted after 3 days. Stents were then covered with endothelial cells and frozen for 4 days. After thawing, the cells adhered to the devices and divided to form a monolayer in tissue culture. Seeded balloon-expandable stents were frozen for 4 months, thawed, and then implanted in a pig coronary artery. Human endothelial cells were identified on the stent 4 hours after deployment. These studies demonstrate the feasibility of using a human microvascular endothelial cell line to seed an uncoated metal stent. The cells remain adherent to the stent, are functional after freezing, and remain on the stent at least 3 hours after intracoronary implantation.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 18 条
[11]   CLINICAL AND ANGIOGRAPHIC OUTCOMES AFTER CORONARY-ARTERY STENTING FOR ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - INITIAL RESULTS WITH A BALLOON-EXPANDABLE, STAINLESS-STEEL DESIGN [J].
HEARN, JA ;
KING, SB ;
DOUGLAS, JS ;
CARLIN, SF ;
LEMBO, NJ ;
GHAZZAL, ZMB .
CIRCULATION, 1993, 88 (05) :2086-2096
[12]  
KEMPCZINSKI RF, 1987, SURGERY, V101, P439
[13]   INTRAVASCULAR STENTS - TISSUE-STENT INTERACTIONS AND DESIGN CONSIDERATIONS [J].
PALMAZ, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :613-618
[14]  
ROUBIN GS, 1992, CIRCULATION, V83, P916
[15]   CLINICAL-EXPERIENCE WITH THE PALMAZ-SCHATZ CORONARY STENT - INITIAL RESULTS OF A MULTICENTER STUDY [J].
SCHATZ, RA ;
BAIM, DS ;
LEON, M ;
ELLIS, SG ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
CABIN, HS ;
WALKER, C ;
STAGG, J ;
BUCHBINDER, M ;
TEIRSTEIN, PS ;
TOPOL, EJ ;
SAVAGE, M ;
PEREZ, JA ;
CURRY, RC ;
WHITWORTH, H ;
SOUSA, JE ;
TIO, F ;
ALMAGOR, Y ;
PONDER, R ;
PENN, IM ;
LEONARD, B ;
LEVINE, SL ;
FISH, RD ;
PALMAZ, JC .
CIRCULATION, 1991, 83 (01) :148-161
[16]   INTRAVASCULAR STENTS TO PREVENT OCCLUSION AND RESTENOSIS AFTER TRANS-LUMINAL ANGIOPLASTY [J].
SIGWART, U ;
PUEL, J ;
MIRKOVITCH, V ;
JOFFRE, F ;
KAPPENBERGER, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (12) :701-706
[17]  
TRIANA JF, 1992, CIRCULATION, V86, P113
[18]  
Van Der Giessen WJ, 1988, J INTERV CARDIOL, V1, P109, DOI DOI 10.1111/J.1540-8183.1988.TB00395.X