INTERVENTIONAL TECHNIQUES FOR THE MANAGEMENT OF CORONARY-ARTERY LESIONS - AN UPDATE

被引:7
作者
DEFEYTER, PJ
MACLEOD, DC
FOLEY, D
DEJAEGERE, PPT
SERRUYS, PW
机构
[1] Catheterization Laboratory, Thoraxcenter, Erasmus University Rotterdam, Rotterdam
关键词
CORONARY ANGIOPLASTY; STENTS; LASERS; ATHERECTOMY;
D O I
10.1002/clc.4960160806
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary balloon angioplasty has become standard treatment for ischemic coronary artery disease. Major limitations of angioplasty are the inferior results obtained with unfavorable lesions, the occurrence of abrupt occlusion responsible for in-hospital mortality and morbidity, and the high restenosis rate at 6 months. New techniques for stents, laser, and atherectomy have been developed to overcome these limitations. Until now, although the initial-results are encouraging, these new techniques have not as yet shown to be clearly superior to balloon angioplasty. However, due to the limitations of balloon angioplasty, further development of new techniques should be stimulated so that nonsurgical treatment of coronary artery disease will become safer, more effective, and applicable to a wider spectrum of coronary artery disease.
引用
收藏
页码:586 / 593
页数:8
相关论文
共 70 条
[51]   INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
ROUBIN, GS ;
CANNON, AD ;
AGRAWAL, SK ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
BRELAND, J .
CIRCULATION, 1992, 85 (03) :916-927
[52]   CORONARY ATHERECTOMY - CLINICAL, ANGIOGRAPHIC, AND HISTOLOGICAL-FINDINGS AND OBSERVATIONS REGARDING POTENTIAL MECHANISMS [J].
SAFIAN, RD ;
GELBFISH, JS ;
ERNY, RE ;
SCHNITT, SJ ;
SCHMIDT, DA ;
BAIM, DS .
CIRCULATION, 1990, 82 (01) :69-79
[53]   USEFULNESS OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY FOR UNSTABLE ANGINA-PECTORIS AFTER NON-Q-WAVE ACUTE MYOCARDIAL-INFARCTION [J].
SAFIAN, RD ;
SNYDER, LD ;
SYNDER, BA ;
MCKAY, RG ;
LORELL, BH ;
AROESTY, JM ;
PASTERNAK, RC ;
BRADLEY, AB ;
MONRAD, ES ;
BAIM, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04) :263-266
[54]  
SAVAS V, 1992, Journal of the American College of Cardiology, V19, p34A
[55]  
SCHATZ RA, 1990, CIRCULATION, V82, P540
[56]   CLINICAL-EXPERIENCE WITH THE PALMAZ-SCHATZ CORONARY STENT - INITIAL RESULTS OF A MULTICENTER STUDY [J].
SCHATZ, RA ;
BAIM, DS ;
LEON, M ;
ELLIS, SG ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
CABIN, HS ;
WALKER, C ;
STAGG, J ;
BUCHBINDER, M ;
TEIRSTEIN, PS ;
TOPOL, EJ ;
SAVAGE, M ;
PEREZ, JA ;
CURRY, RC ;
WHITWORTH, H ;
SOUSA, JE ;
TIO, F ;
ALMAGOR, Y ;
PONDER, R ;
PENN, IM ;
LEONARD, B ;
LEVINE, SL ;
FISH, RD ;
PALMAZ, JC .
CIRCULATION, 1991, 83 (01) :148-161
[57]  
SCOTT N A, 1992, Journal of the American College of Cardiology, V19, p93A
[58]  
SELMON MR, 1991, CIRCULATION S2, V84, P80
[59]  
SERRUYS PW, 1991, J AM COLL CARDIOL, V17, pB143
[60]   ANGIOGRAPHIC FOLLOW-UP AFTER PLACEMENT OF A SELF-EXPANDING CORONARY-ARTERY STENT [J].
SERRUYS, PW ;
STRAUSS, BH ;
BEATT, KJ ;
BERTRAND, ME ;
PUEL, J ;
RICKARDS, AF ;
MEIER, B ;
GOY, JJ ;
VOGT, P ;
KAPPENBERGER, L ;
SIGWART, U .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (01) :13-17