RADIOLOGIC EVALUATION OF THE INTRAVENOUS OXYGENATOR

被引:1
作者
SHUKLA, PR
SNIDER, MT
HOPPER, KD
THIEME, GA
MEILSTRUP, JW
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT ANESTHESIA,HERSHEY,PA 17033
[2] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT RADIOL,500 UNIV DR,HERSHEY,PA 17033
[3] PENN STATE UNIV,MILTON S HERSHEY MED CTR,COLL MED,HERSHEY,PA 17033
关键词
OXYGEN; OXYGENATOR; INTRAVENOUS; RESPIRATORY DISTRESS SYNDROME; ADULT; (ARDS); THORAX; INTERVENTIONAL PROCEDURE; ULTRASOUND; (US); INTRAOPERATIVE;
D O I
10.1148/radiology.187.3.8497630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This report describes the radiologic appearance of the intravenous oxygenator (IVOX), an intracorporeal CO2-O2 exchanger for use in patients with severe respiratory deficiency, and the extensive radiographic and sonographic support required for its use. Six patients aged 19-39 years who had severe adult respiratory distress syndrome (ARDS) and who were not expected to survive were selected for IVOX placement; ARDS was caused by trauma (four patients), severe pneumonia (one patient), or a fat embolus from a tibial fracture (one patient). Before insertion of the IVOX, all patients underwent evaluation of their right internal jugular vein, right common femoral vein, and inferior vena cava with real-time ultrasound (US) to ascertain vascular size. The IVOX improved oxygenation in all patients; because of such improvement, one patient survived. Use of the IVOX may become common; hence, radiologists should understand how the IVOX functions and its appropriate placement, be able to identify it on chest and abdominal radiographs, and appreciate the importance of US in placement of this device and follow-up.
引用
收藏
页码:783 / 786
页数:4
相关论文
共 8 条
  • [1] COX C S JR, 1991, Perfusion (London), V6, P291, DOI 10.1177/026765919100600409
  • [2] CLINICAL-TRIALS OF AN INTRAVENOUS OXYGENATOR IN PATIENTS WITH ADULT RESPIRATORY-DISTRESS SYNDROME
    HIGH, KM
    SNIDER, MT
    RICHARD, R
    RUSSELL, GB
    STENE, JK
    CAMPBELL, DB
    AUFIERO, TX
    THIEME, GA
    [J]. ANESTHESIOLOGY, 1992, 77 (05) : 856 - 863
  • [3] Jurmann M J, 1992, ASAIO J, V38, P120, DOI 10.1097/00002480-199204000-00011
  • [4] CONCEPTUAL AND DESIGN-FEATURES OF A PRACTICAL, CLINICALLY EFFECTIVE INTRAVENOUS MECHANICAL BLOOD-OXYGEN CARBON-DIOXIDE EXCHANGE DEVICE (IVOX)
    MORTENSEN, JD
    BERRY, G
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (06) : 384 - 389
  • [5] MORTENSEN JD, 1987, T AM SOC ART INT ORG, V33, P570
  • [6] SEIDEL DF, 1991, J AM ACAD CARDIOVASC, V12, P27
  • [7] SNIDER MT, 1989, ANESTHESIOLOGY, V71, pA1096
  • [8] EXTRACORPOREAL MEMBRANE-OXYGENATION IN SEVERE ACUTE RESPIRATORY-FAILURE - RANDOMIZED PROSPECTIVE-STUDY
    ZAPOL, WM
    SNIDER, MT
    HILL, JD
    FALLAT, RJ
    BARTLETT, RH
    EDMUNDS, LH
    MORRIS, AH
    PEIRCE, EC
    THOMAS, AN
    PROCTOR, HJ
    DRINKER, PA
    PRATT, PC
    BAGNIEWSKI, A
    MILLER, RG
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1979, 242 (20): : 2193 - 2196